33 models found
·
28 public code
·
17 public weights
Lightweight convolutional neural network for binary ECG classification that represents ECG beats as spectrograms (via short-time Fourier transform) rather than raw signals, after denoising and frequency filtration to reduce data volume while preserving diagnostically relevant information. Using the large public PTB-XL dataset, the spectrogram-based CNN reached 99.06% accuracy, outperforming an equivalent raw-signal CNN, while also reducing memory usage and computation by avoiding complex architectures; the authors additionally studied the effect of signal up/down-sampling on classification performance.
Model ID: 0153
·
Subject Count: 18,885
CNN-based arrhythmia classifier that fuses the magnitude (scalogram) and phase (phasogram) of the continuous wavelet transform (CWT) of ECG heartbeats, rather than relying on magnitude information alone as most prior 2D-representation approaches do. Several fusion strategies (input-level, intermediate-layer, and output-level fusion) were compared on the public PhysioNet MIT-BIH Arrhythmia database. Despite a simple CNN architecture, the best fusion strategy achieved about 98.5% overall accuracy, 98.5% sensitivity and 95.6% specificity, competitive with more complex state-of-the-art approaches.
Model ID: 0143
·
Subject Count: 47
Automated deep learning workflow that detects and grades tricuspid regurgitation (TR) severity from full transthoracic echocardiography studies. The pipeline first identifies apical-4-chamber (A4C) video clips with color Doppler across the tricuspid valve from a full echo study, then applies a dedicated R(2+1)D video classifier to grade TR severity. Trained on over 2 million echo videos from 47,312 studies at Cedars-Sinai Medical Center and externally validated at Stanford Healthcare, the model identified color-Doppler A4C views with AUC ≥0.999 and detected clinically significant (moderate-or-severe) TR with AUC 0.951 and severe TR with AUC 0.980. Code and trained model weights are released to support prospective evaluation of AI-assisted TR screening.
Model ID: 0122
Multi-label 12-lead ECG diagnosis model submitted to the PhysioNet/Computing in Cardiology Challenge 2020, built on the same residual 1D CNN family as the authors' earlier Nature Communications model but retrained and validated across the challenge's large, multi-institutional pooled training set (CPSC2018, China 12-Lead ECG Database, St. Petersburg INCART, PTB and PTB-XL, and the Georgia 12-Lead ECG Database). The model uses an unsupervised pretraining stage -- predicting unseen samples of a partially masked ECG signal -- before supervised fine-tuning to jointly detect nine diagnostic classes (atrial fibrillation, first-degree AV block, left and right bundle branch block, normal rhythm, premature atrial/ventricular contraction, and ST-segment depression/elevation). The 2020 Challenge was notable for requiring every team to publicly release both their trained model weights and full training code, making this one of relatively few 12-lead ECG classifiers with an end-to-end reproducible public pipeline.
Model ID: 0118
·
Subject Count: 19,185
nnU-Net-based pipeline for automated detection and sub-classification of acute thoracic aortic dissection (AD) on heterogeneous CT imaging, formulated as a semantic segmentation task rather than direct image classification. The model segments the false lumen (ascending and descending) and the dissection membrane -- along with optional indirect signs such as hemopericardium, aortic wall hematoma, and supra-aortic branch dissection -- and a patient is classified as AD-positive if at least two of the three primary segmented regions exceed a volume threshold tuned via Youden's index; the same pipeline additionally flags Stanford type A dissections. Trained on 157 heterogeneous internal CT studies (not restricted to a single contrast protocol) from Mannheim University Medical Centre and evaluated on an internal held-out test set as well as public external datasets (ImageTBAD and AVT), the model reached an AUROC of 98.7% internally and 97.0% externally, and correctly flagged 93.3% of dissection cases that had not been clinically suspected before imaging. The authors state the trained network will be made publicly available as a non-medical device for further scientific research.
Model ID: 0113
·
Subject Count: 263
Two-stage convolutional neural network that automatically detects and anatomically labels coronary artery, thoracic aorta, and cardiac-valve calcifications in low-dose chest CT acquired for lung-cancer screening. A first CNN with a large receptive field (via dilated convolutions) identifies and anatomically labels candidate calcifications; a second CNN filters true positives from the candidates. Trained and evaluated on 1,744 CT scans from the National Lung Screening Trial (NLST), reaching an F1 of 0.89 (soft-filter reconstructions) / 0.84 (sharp-filter reconstructions) for coronary artery calcifications and a linearly-weighted kappa of 0.90-0.91 for per-subject cardiovascular risk categorization versus the manual reference standard.
Model ID: 0102
·
Subject Count: 1,744
Dual Bayesian ResNet model for heart murmur detection from multi-location phonocardiogram (PCG) recordings, developed for the George B. Moody PhysioNet Challenge 2022. Each patient's PCG recordings are segmented into overlapping log-mel spectrograms, which are passed through two Bayesian ResNet binary classifiers running simultaneously (present vs. unknown-or-absent, and unknown vs. present-or-absent); the two outputs are aggregated into a patient-level present/unknown/absent murmur classification. An optional second-stage XGBoost model integrates the DBRes output with demographic data and hand-crafted signal features. On the Challenge's official hidden test set, DBRes achieved a weighted accuracy of 0.771 for the murmur-detection task, placing 4th among all teams.
Model ID: 0108
·
Subject Count: 1,568
Deep learning pipeline for detection and quantification of abdominal aortic aneurysm (AAA) -- a typically asymptomatic condition often missed incidentally by radiologists -- from abdominal-pelvic CT. A modified 3D U-Net segments the aorta on both contrast and non-contrast CT volumes with a variable number of images, after which an ellipse-fitting post-processing step measures the aortic cross-sectional diameter along the vessel to detect aneurysmal dilation. Trained and validated on 321 abdominal-pelvic CT examinations from Massachusetts General Hospital, the model reached a sensitivity/specificity of 0.91/0.95 on the primary validation set, and 0.85/1.0 on a separate 57-exam generalization test set with different patient demographics and acquisition characteristics; the authors report that DeepAAA exceeded literature-reported radiologist performance for incidental AAA detection.
Model ID: 0114
·
Subject Count: 321
Video-based deep learning system for automated screening of rheumatic heart disease (RHD) from echocardiography, aimed at low-resource settings where RHD -- the most common acquired heart disease in children and young adults worldwide -- is endemic but echocardiography expertise is scarce. A 3D convolutional neural network (C3D) classifies each echo video clip, explicitly modeling temporal information across frames; a supervised meta-classifier then aggregates the per-video predictions from an exam (which may contain many video clips from different views) into a single exam-level RHD diagnosis. Evaluated on 11,646 echocardiography videos from 912 screening exams collected in underserved areas of Brazil and Uganda, the 3D C3D network significantly outperformed a comparison 2D CNN (VGG16) that ignores temporal information, and the learned aggregation model reached 72.77% exam-level diagnostic accuracy, exceeding simple majority voting across a patient's videos.
Model ID: 0120
·
Subject Count: 912
U-Net-variant segmentation model that identifies and quantifies coronary artery calcium (CAC) directly from routine non-gated, non-contrast chest CT scans -- the kind ordered for lung-cancer screening or unrelated indications rather than a dedicated cardiac scan -- so that the tens of millions of such scans performed annually can be opportunistically screened for cardiovascular risk without any extra imaging. Predicted calcium masks are combined with the CT's Hounsfield units to compute an Agatston-equivalent score. Trained on 446 expert-segmented scans from 98 medical centers across the U.S. Department of Veterans Affairs national health system (capturing substantial heterogeneity in scanners and protocols) and benchmarked against 795 patients with a paired same-year gated CAC study: nongated AI-CAC differentiates zero-vs-nonzero and <100-vs->=100 Agatston categories with 89.4% (F1 0.93) and 87.3% (F1 0.89) accuracy respectively, and its score stratifies 10-year all-cause mortality (CAC 0 vs. >400: 25.4% vs. 60.2%, hazard ratio 3.49) and composite stroke/MI/death risk (33.5% vs. 63.8%, hazard ratio 3.00). In a simulated opportunistic-screening run across 8,052 low-dose CT scans, cardiologists confirmed 99.2% of patients flagged with AI-CAC >400 would benefit from lipid-lowering therapy. Code and trained model weights are both public under an MIT license.
Model ID: 0099
Multi-outcome AI-ECG risk-estimation platform that turns a single 12-lead ECG into a patient-specific survival curve, using a residual convolutional neural network trained with a discrete-time survival loss to predict not just risk but time-to-event. Beyond all-cause and cardiovascular mortality, separately fine-tuned heads predict future ventricular arrhythmia, complete heart block, atrial fibrillation, atherosclerotic cardiovascular disease, heart failure, and (in follow-up work) hypertension -- all from a single resting ECG, including in ECGs a cardiologist would read as normal. Derived on 1.16 million ECGs from 189,539 Beth Israel Deaconess Medical Center patients and externally validated across transnational cohorts in the USA, Brazil (CODE), and the UK (UK Biobank). A variational autoencoder and genome/phenome-wide association analyses were used to show the model's predictions track biologically plausible features (QRS morphology, LV structure/function, and loci linked to cardiac structure, QT interval, and biological aging). NHS trials of AIRE were planned for late 2025. No public code or model weights have been released.
Model ID: 0089
·
Subject Count: 189,539
ECG-guided photoplethysmography (PPG) foundation model pretrained on over 100,000 hours of synchronized PPG-ECG recordings from 58,796 subjects across five clinical and wearable sources, using a CLIP-style contrastive alignment framework so the PPG encoder inherits physiologically grounded structure from paired ECG. Achieves state-of-the-art performance on 13 of 15 conventional physiological-analysis tasks across eight datasets, and shows meaningful discriminative capability (AUC >= 0.70) for 307 ICD-10-coded phenotypes across 16 phecode chapters, including many non-cardiovascular conditions.
Model ID: 0067
·
Subject Count: 58,796
Multimodal deep-learning framework that estimates and forecasts abnormal laboratory values directly from a 12-lead ECG plus routinely available demographics, biometrics, and vital signs -- reframing dozens of blood tests as binary classification targets predictable from a test that is already fast, non-invasive, and nearly universal in acute care. A structured state-space (S4) encoder processes the raw ECG waveform and is late-fused with an MLP encoder over the tabular metadata; the same architecture is trained both to estimate the closest lab value within 60 minutes of the ECG ('abnormality prediction') and to forecast whether a value will become abnormal 30/60/120 minutes into the future ('abnormality forecasting'). Trained and evaluated on 385,480 linked ECG-lab-value samples from 127,994 MIMIC-IV patients, the model reaches AUROC > 0.7 for 24 distinct lab abnormalities in the prediction setting and 24 in the forecasting setting, spanning cardiac, renal, hematological, metabolic, immunological, and coagulation categories -- with NT-proBNP elevation the best-predicted marker (AUROC 0.90), followed by hemoglobin, albumin, and hematocrit derangements (AUROC > 0.82). Code for dataset construction, training, and evaluation is public under an MIT license; no pretrained model weights are released.
Model ID: 0100
·
Subject Count: 127,994
Supervised EfficientNetV2-based 12-lead ECG model trained on over 1 million ECGs from the Montreal Heart Institute to predict 77 cardiac conditions derived from American Heart Association recommendations, plus fine-tuned digital-biomarker heads for reduced LVEF, 5-year atrial-fibrillation risk, and long-QT-syndrome (LQTS) detection/genotyping. Validated on 881,403 ECGs across 11 geographically diverse cohorts (4 public, 7 private health systems), achieving AUROCs above 0.98 for the 77-condition interpretation task while being 60x smaller and 29x faster at inference than its self-supervised DeepECG-SSL counterpart, with up to 9.7x lower CO2 emissions on equivalent tasks.
Model ID: 0070
·
Subject Count: 184,210
Self-supervised EfficientNetV2-based 12-lead ECG foundation model pretrained via contrastive learning and masked-lead modeling on 1.9 million ECGs (Montreal Heart Institute plus CODE-15% and MIMIC-IV), then fine-tuned for the same 77-condition ECG interpretation task and digital-biomarker extraction as DeepECG-SL. Outperforms the supervised counterpart on label-scarce digital-biomarker tasks, with the largest gains on LQTS genotype classification (AUROC 0.931 vs. 0.850, n=127 ECGs) and 5-year atrial-fibrillation risk (AUROC 0.742 vs. 0.734, n=132,050 ECGs), and outperforms ECG-FM and ECGFounder on shared external diagnostic classes.
Model ID: 0071
·
Subject Count: 345,562
Open-weight video-based deep neural network that predicts reduced right-ventricular systolic function (RVSF) directly from routine left and right coronary angiogram videos, enabling real-time RV-dysfunction screening in the catheterization lab when echocardiography is unavailable. Built on an X3D-M spatiotemporal video architecture (Kinetics-400 pretrained) that aggregates per-video probabilities into a study-level normal-vs-reduced RVSF classification, with Grad-CAM/Guided-Backpropagation explainability confirming attention to RV-specific coronary motion rather than left-ventricular signal. Trained on 8,053 angiographic studies from 6,923 Montreal Heart Institute patients (2017-2023), externally validated at UCSF, and prospectively deployed at MHI via the PACS-AI platform, where AI assistance improved reader accuracy from 72.1% to 77.6% for cardiologists and 43.5% to 64.0% for medical students.
Model ID: 0073
·
Subject Count: 6,923
Explainable Inception-style 1D CNN for multi-label arrhythmia detection from 12-lead ECGs, integrating Grad-CAM visualization to highlight the waveform segments driving each prediction. Trained on MIMIC-IV-ECG and externally validated on PTB-XL across atrial fibrillation, sinus tachycardia, conduction disturbances (RBBB/LBBB/LAFB), long QT, Wolff-Parkinson-White pattern, and paced-rhythm detection, with all metrics exceeding 90% internally and strong generalization on external validation.
Model ID: 0064
·
Subject Count: 161,352
Multi-instance contrastive self-supervised learning framework for echocardiography video representation learning: two distinct videos from the same patient exam are treated as positive pairs (rather than augmentations of a single clip), and a frame-reordering pretext task on temporally shuffled frames encourages the 3D-CNN backbone to learn temporally coherent representations. After self-supervised pretraining on unlabeled echocardiograms, the backbone is efficiently fine-tuned for cardiac disease classification (severe aortic stenosis, left ventricular hypertrophy) using very few labeled examples, outperforming SimCLR, standard multi-instance SimCLR, and Kinetics-400-initialized baselines across a range of training-data ratios.
Model ID: 0077
Predicts cardiac MRI (CMR) tissue-characterization findings -- wall-motion abnormalities and myocardial scar -- directly from standard transthoracic echocardiography videos (A4C/A2C/PLAX views), using a factorized 3D R2+1D convolutional network. Trained and validated on a single-institution cohort of more than 1,400 patients with paired echo and CMR studies within 30 days of each other. Released weights and inference code cover the two binarized outcomes (wall motion, scar); the continuous CMR tissue markers (native T1, T2, ECV) evaluated in the paper are not part of the public release.
Model ID: 0060
Ensemble of 3D convolutional neural networks that detects severe aortic stenosis directly from single-view 2D parasternal long-axis (PLAX) transthoracic echocardiogram videos, without requiring Doppler imaging. Representations are first pretrained with patient-level contrastive self-supervised learning on PLAX clips, then fine-tuned for binary AS classification; the ensemble is externally validated across a temporally-distinct cohort and geographically-distinct cohorts in California and New England. No pretrained weights are released; only the training/evaluation pipeline is public.
Model ID: 0059
Self-supervised foundation model for photoplethysmography (PPG) that explicitly targets the low-signal-quality problem endemic to real-world wearable and bedside PPG, rather than assuming clean input. A Siamese ResNet (SimSiam-style) encoder is pretrained to produce similar representations for temporally-adjacent high- and low-quality PPG segments presumed to share the same underlying physiological state, with curriculum learning that gradually increases the artifact-level gap between paired segments. Pretrained on over 36 million 30-second PPG pairs drawn from more than 24,100 UCSF ICU patients, then fine-tuned and evaluated on six downstream cardiovascular-monitoring datasets/tasks (heart rate, respiratory rate, blood pressure, and atrial-fibrillation detection), where it exceeds prior state-of-the-art by roughly 75% on respiratory-rate estimation and 5% on AF detection, with performance scaling with backbone depth (ResNet152 best). Code and the pretraining dataset are not public; the pretraining data is available upon request under a UCSF-Emory data use agreement.
Model ID: 0097
·
Subject Count: 24,100
ECG foundation model designed to remain accurate when leads are missing or signals are noisy. A 1D ConvNeXt V2 encoder is trained with a dual-mode self-distillation objective (separate lead-missing and noise "teachers") alongside contrastive alignment to detailed diagnostic-criteria text reports retrieved via a lightweight, LLM-free "Cardiac Feature Retrieval" module. Consistently ranks best or second-best across PTB-XL diagnostic tasks and MIT-BIH arrhythmia classification under original, noisy, lead-missing, and combined-corruption conditions. Developed by FPT Software AI Center and the University of Arkansas.
Model ID: 0057
·
Subject Count: 180,237
Video-based deep learning model that grades aortic regurgitation (AR) severity—none/trace, mild, moderate, or severe—from color Doppler echocardiography. View-specific R(2+1)D 3D-CNNs analyze five standard transthoracic views (PLAX, PLAX-AV, A3C, A3C-AV, A5C) and their outputs are combined by a maximum-severity rule at the study level. Trained on ~47,600 color Doppler videos from Cedars-Sinai and externally validated at Stanford Healthcare, reaching AUCs of 0.95 for at-least-moderate AR and 0.97 for severe AR internally. Developed by the Ouyang lab at Cedars-Sinai Medical Center.
Model ID: 0053
Video-based deep learning model that estimates 14 common blood biomarkers and laboratory values—including hemoglobin (anemia), B-type natriuretic peptide (BNP), troponin I, and blood urea nitrogen (BUN)—directly from apical-4-chamber echocardiogram videos. Built on a spatiotemporal convolutional network (R(2+1)D-style) with residual connections that produces beat-by-beat estimates for both regression and abnormality classification. Trained on over 70,000 echocardiograms from Stanford Healthcare and externally validated at Cedars-Sinai, reaching AUCs around 0.80–0.86 for detecting anemia and elevated BNP. Developed by the Ouyang and Zou labs at Stanford University and Cedars-Sinai.
Model ID: 0052
Deep learning model for automated phenotyping of mitral stenosis (MS) from echocardiography. Uses video-based R(2+1)D convolutional networks on color Doppler and B-mode views to identify and grade mitral stenosis severity, following the multi-view valvular-assessment approach of the EchoNet family. Trained and validated on large clinical echocardiography cohorts from Kaiser Permanente Northern California with external testing at Stanford Healthcare and Cedars-Sinai. Developed by the Ouyang lab.
Model ID: 0055
CNN-based image classifier that screens 12-lead ECG images for a signature of transthyretin amyloid cardiomyopathy (ATTR-CM), producing a study-level probability score. Trained on a private Yale New Haven Health System cohort of nuclear-imaging-confirmed ATTR-CM cases and matched controls. Used alongside a companion echocardiography model to track pre-clinical ATTR-CM progression years before it would otherwise be confirmed by nuclear amyloid imaging. Developed by Yale's CarDS Lab and distributed as a packaged research-use executable rather than downloadable weights.
Model ID: 0024
EfficientNet-B3 CNN that detects hypertrophic cardiomyopathy directly from images of printed or scanned 12-lead ECGs, rather than from raw digital waveforms, enabling screening from a photo of a paper tracing. Initialized via self-supervised contrastive pretraining on patient identity, then fine-tuned at Yale New Haven Hospital on over 124,000 ECGs from about 67,000 patients, with HCM status confirmed by cardiac MRI or echocardiography. Externally validated on ECG images from MIMIC-IV, Amsterdam UMC, and UK Biobank. Developed by Yale's CarDS Lab.
Model ID: 0025
·
Subject Count: 66,987
Screens 12-lead ECGs for Chagas cardiomyopathy by first pretraining a feature extractor to predict blood-biomarker levels from MIMIC-IV-ECG data, then fine-tuning on Brazilian CODE-15%, SaMi-Trop, and PTB-XL recordings; the final model is a 5-model ensemble. Submitted to the George B. Moody PhysioNet Challenge 2025 (Detection of Chagas Disease from the ECG), where it placed 5th on the official leaderboard. Developed by a team from Akershus University Hospital and the University of Oslo.
Model ID: 0012
·
Subject Count: 1,631
1D residual neural network that screens 10-second, 12-lead ECG tracings for six common abnormalities: first- and second-degree AV block patterns, right and left bundle branch block, sinus bradycardia, atrial fibrillation, and sinus tachycardia. Reported F1 scores above 80% and specificity over 99% when benchmarked against cardiology residents. Developed at Universidade Federal de Minas Gerais and trained on the large Brazilian CODE-15% ECG dataset.
Model ID: 0010
Multi-task model that jointly assesses signal quality and detects atrial fibrillation from wrist-worn wearable photoplethysmography (PPG), pretrained on roughly one million simulated unlabeled signals before fine-tuning on labeled wearable data. Uses a 1D CNN with separate output heads for signal quality and arrhythmia detection. Developed by Stanford's Ashley Lab.
Model ID: 0046
·
Subject Count: 100
Multi-task 12-lead ECG model with output heads for incident atrial-fibrillation risk (as a survival curve), incident mortality risk, prevalent AF classification, sex classification, and age regression. Built on a 1D CNN over the raw waveform, and developed by the Broad Institute's ML4H group as a successor to their ECG-AI model published in Circulation. Trained on ECGs from UK Biobank and Massachusetts General Hospital, neither of which is publicly released.
Model ID: 0016
·
Subject Count: 45,770
Large-scale ECG foundation model pretrained on more than 10 million recordings spanning 150 label categories from the Harvard-Emory ECG Database. Built as a general-purpose feature extractor that can be fine-tuned for arrhythmia detection, demographic inference, and event prediction, and externally validated on MIMIC-IV-ECG and PTB-XL. Also used as the pretrained backbone for downstream clinical models such as Pocket-K, a hyperkalemia detector. Developed by Peking University and Harvard-Emory researchers.
Model ID: 0017
Reference benchmark suite for the PTB-XL ECG dataset, providing pretrained xresnet1d, InceptionTime, LSTM, and CPC-pretrained models for 71-label, diagnostic, sub-diagnostic, and super-diagnostic classification of ECG findings. Widely used as a standardized baseline for comparing new ECG classification methods. Developed by Strodthoff et al. at Fraunhofer HHI.
Model ID: 0029
·
Subject Count: 18,885