4 models found
·
4 public code
·
3 public weights
Foundation vision-language model for cardiac MRI that learns pathophysiological visual representations directly from the natural-language radiology reports accompanying each scan, rather than from hand-labeled targets. A Multi-scale Vision Transformer (MViT, Kinetics-400-initialized) video encoder for cine CMR sequences is contrastively pretrained (InfoNCE) against a PubMed-pretrained BERT text encoder over 19,041 multi-institutional CMR studies. The frozen vision encoder transfers with strong performance to left-ventricular ejection-fraction regression (MAE 3.34% on a UK Biobank hold-out of ~4,259-45,623 participants) and detecting HFrEF (LVEF<40%, AUC 0.880), and the paper reports emergent zero-/few-shot performance across 39 cardiac and non-cardiac conditions including cardiac amyloidosis and hypertrophic cardiomyopathy. Code and pretrained MViT encoder weights are both released (Hugging Face, CC BY-NC 4.0).
Model ID: 0093
Vision-language model that jointly embeds a cardiac MRI study, treated as video, with the impression section of its clinical report. Combines a video encoder over cine/LGE frame sequences with a Bio+ClinicalBERT text encoder using CLIP-style contrastive training. Supports zero-shot and few-shot classification of cardiomyopathies, amyloidosis, and LV dysfunction, plus image/report retrieval and structured report drafting. Trained on a private, single-institution corpus of roughly 11,000-14,000 CMR study-report pairs from Cleveland Clinic and Case Western.
Model ID: 0007
·
Subject Count: 12,500
Vision-language foundation model fine-tuned from CLIP on more than one million private echocardiogram video-report pairs, enabling zero-shot cardiac function assessment, device identification, and image/text retrieval without task-specific training. Combines a ConvNeXt-Base video encoder with a GPT-2-style text encoder under contrastive pretraining. Training data is private, but model weights and code are public. Developed by Cedars-Sinai's Ouyang lab.
Model ID: 0035
CLIP-style model that aligns 12-lead ECG signals with free-text echocardiography reports for zero-shot detection of structural heart disease directly from an ECG. Extends the MERL framework, and was trained on 45,016 paired ECG-echo reports from two Hong Kong hospitals, with external validation on the public EchoNext dataset from Columbia University. Developed by researchers at the University of Hong Kong and Imperial College London; described in a 2025 medRxiv preprint.
Model ID: 0045