5 models found
·
4 public code
·
3 public weights
Supervised EfficientNetV2-based 12-lead ECG model trained on over 1 million ECGs from the Montreal Heart Institute to predict 77 cardiac conditions derived from American Heart Association recommendations, plus fine-tuned digital-biomarker heads for reduced LVEF, 5-year atrial-fibrillation risk, and long-QT-syndrome (LQTS) detection/genotyping. Validated on 881,403 ECGs across 11 geographically diverse cohorts (4 public, 7 private health systems), achieving AUROCs above 0.98 for the 77-condition interpretation task while being 60x smaller and 29x faster at inference than its self-supervised DeepECG-SSL counterpart, with up to 9.7x lower CO2 emissions on equivalent tasks.
Model ID: 0070
·
Subject Count: 184,210
Self-supervised EfficientNetV2-based 12-lead ECG foundation model pretrained via contrastive learning and masked-lead modeling on 1.9 million ECGs (Montreal Heart Institute plus CODE-15% and MIMIC-IV), then fine-tuned for the same 77-condition ECG interpretation task and digital-biomarker extraction as DeepECG-SL. Outperforms the supervised counterpart on label-scarce digital-biomarker tasks, with the largest gains on LQTS genotype classification (AUROC 0.931 vs. 0.850, n=127 ECGs) and 5-year atrial-fibrillation risk (AUROC 0.742 vs. 0.734, n=132,050 ECGs), and outperforms ECG-FM and ECGFounder on shared external diagnostic classes.
Model ID: 0071
·
Subject Count: 345,562
Foundation model that encodes single-lead (lead I) ECGs with information from paired transthoracic echocardiography reports, aimed at label-efficient screening for structural heart disease (SHD) on wearable and portable single-lead ECG devices. A 7-layer 1D-CNN ECG encoder and a RoBERTa-based text encoder are contrastively pretrained (CLIP-style) on 194,551 ECG-echo report pairs from 77,378 adults in the Yale New Haven Health System, then the ECG encoder is fine-tuned on a temporally-distinct cohort to detect reduced LVEF, diastolic dysfunction, and a composite SHD label. Matches a randomly-initialized CNN at full training-data volume but substantially outperforms it in label-scarce regimes (e.g. with only 0.5% of labeled data).
Model ID: 0066
·
Subject Count: 77,378
Open ECG foundation model with 90.9M parameters, built on a wav2vec 2.0-style Transformer and pretrained on 1.25-1.5 million ECGs using a hybrid contrastive-and-generative self-supervised objective. Base pretrained weights and MIMIC-IV-ECG-finetuned downstream checkpoints are both released. Developed on the fairseq_signals framework by the University of Toronto / Vector Institute's Wang lab.
Model ID: 0020
·
Subject Count: 161,352
CLIP-style model that aligns 12-lead ECG signals with free-text echocardiography reports for zero-shot detection of structural heart disease directly from an ECG. Extends the MERL framework, and was trained on 45,016 paired ECG-echo reports from two Hong Kong hospitals, with external validation on the public EchoNext dataset from Columbia University. Developed by researchers at the University of Hong Kong and Imperial College London; described in a 2025 medRxiv preprint.
Model ID: 0045