15 models found
·
14 public code
·
9 public weights
Complete motion-analysis workflow for the left atrium (LA) using 3D Cine MRI, combining an online-learning segmentation network with an image-registration network to compute LA displacement vector fields (DVF) and principal strains across the cardiac cycle. Validated on 10 healthy volunteers and 8 cardiovascular disease patients, Aladdin accurately tracks LA wall motion and can identify regional deformation abnormalities that may indicate focal pathology, agreeing well with 2D Cine MRI global function estimates.
Model ID: 0139
·
Subject Count: 18
Self-supervised multi-encoder autoencoder (MEAE) that separates heartbeat-related source signals from noisy photoplethysmogram (PPG) via blind source separation, improving heart-rate detection without requiring any pre-processing or manual data selection. Trained entirely on PPG signals from a large open polysomnography database (with no cleaning or curation), the model is then applied to a noisy real-world PPG dataset collected during daily activities of 9 subjects and a surgical dataset of 4,681 patients; the extracted heartbeat-related source signal significantly improves heart-rate detection accuracy compared with using the raw PPG signal directly.
Model ID: 0162
Open-source, vendor-agnostic deep learning pipeline that retrospectively measures left ventricular global longitudinal strain (GLS) from routine apical-4-chamber echocardiography B-mode video, without requiring speckle-tracking software or manual tracing. The pipeline reuses EchoNet-Dynamic's LV semantic-segmentation network to trace the LV endocardial border frame-by-frame, then measures the frame-to-frame change in traced myocardial length across the cardiac cycle to derive GLS. In external validation against a large 3D-echocardiography-derived GLS dataset and a prospective two-sonographer, two-vendor repeated-measures study, the automated strain measurement showed lower inter- and intra-measurement variability than human readers and moderate agreement with reference speckle-tracking strain (ICC 0.58), while being robust to image-quality differences and vendor.
Model ID: 0121
·
Subject Count: 10,030
Pediatric-specific extension of EchoNet-Dynamic: a video-based deep learning model that segments the left ventricle and estimates ejection fraction (EF) from apical-4-chamber (A4C) and parasternal short-axis (PSAX) pediatric echocardiogram clips. Because adult-trained echo models generalize poorly to children (who vary widely in heart size, rate, and image quality), EchoNet-Peds was trained from scratch on a dedicated pediatric video dataset. It segments the LV with a Dice similarity coefficient of 0.89 in both views, estimates EF with a mean absolute error of 3.66%, and identifies pediatric systolic dysfunction with an AUC of 0.95, significantly outperforming an adult-trained model applied to the same pediatric data.
Model ID: 0126
·
Subject Count: 1,923
Deep learning model that non-invasively estimates cardiac output (CO) from wearable seismocardiography (SCG), a single-lead ECG, and body mass index (BMI), as a potential alternative to invasive right heart catheterization (RHC). Parallel 1D-CNN branches extract features from the SCG and ECG waveforms, which are fused with BMI and passed through a lightweight regression head to predict CO directly. Trained and evaluated via leave-pair-out cross-validation on 73 heart-failure patients (83 RHC encounters) from an open PhysioNet dataset, the model achieved an RMSE of 1.00 L/min (22%) and Pearson correlation of 0.75 versus catheterization-derived CO, with particularly strong performance in low-output states.
Model ID: 0124
·
Subject Count: 73
Foundation vision-language model for cardiac MRI that learns pathophysiological visual representations directly from the natural-language radiology reports accompanying each scan, rather than from hand-labeled targets. A Multi-scale Vision Transformer (MViT, Kinetics-400-initialized) video encoder for cine CMR sequences is contrastively pretrained (InfoNCE) against a PubMed-pretrained BERT text encoder over 19,041 multi-institutional CMR studies. The frozen vision encoder transfers with strong performance to left-ventricular ejection-fraction regression (MAE 3.34% on a UK Biobank hold-out of ~4,259-45,623 participants) and detecting HFrEF (LVEF<40%, AUC 0.880), and the paper reports emergent zero-/few-shot performance across 39 cardiac and non-cardiac conditions including cardiac amyloidosis and hypertrophic cardiomyopathy. Code and pretrained MViT encoder weights are both released (Hugging Face, CC BY-NC 4.0).
Model ID: 0093
Multi-view foundation model for coronary angiography trained with video-text contrastive learning on 203,808 angiography videos from 28,117 patients across 32,473 studies at the Montreal Heart Institute, externally validated on 4,249 studies from UCSF. Integrates multiple angiographic projections with attention-based pooling for study-level assessment spanning diagnostic, prognostic, and disease-progression tasks: significant-stenosis detection (AUROC 0.888 internal / 0.89 external), stenosis-percentage estimation (MAE 13.6% vs. 19.0% for clinical reports), chronic total occlusion, intracoronary thrombus, and coronary calcification detection. Transfer learning further enables one-year MACE prediction (AUROC 0.79) and LVEF estimation (MAE 7.3%) from the same angiography embeddings, with a mean in-hospital inference time of 4.2 seconds.
Model ID: 0075
·
Subject Count: 28,117
Adapts the Segment Anything Model (SAM) to echocardiography video segmentation by giving it a space-time memory that carries both spatial and temporal cues, so that only the first frame of a video needs an external point prompt and every subsequent frame is segmented from a propagated memory prompt instead. A memory reinforcement mechanism uses each frame's predicted mask to suppress speckle-noise features before they are written back into memory, addressing a key failure mode of naively adapting video object segmentation (e.g. XMem) to noisy ultrasound. Built on SAMUS (an ultrasound-adapted SAM) with a frozen SAM backbone and only the image-encoder adapter layers trained. On the semi-supervised CAMUS and EchoNet-Dynamic benchmarks (only end-diastole/end-systole frames labeled), MemSAM reaches 93.3% and 92.8% mean Dice respectively, outperforming UNet, SwinUNet, H2Former, and prior medical-SAM adaptations (MedSAM, MSA, SAMed, SonoSAM, SAMUS) with far fewer prompts, and derives LVEF (via Simpson's biplane method of disks) with a Pearson correlation of 78.9% against ground truth on CAMUS. Training/inference code is public (MIT license); only the starting SAM ViT-B checkpoint is linked for download, not a separately released fine-tuned MemSAM checkpoint.
Model ID: 0098
·
Subject Count: 10,530
Foundation model that encodes single-lead (lead I) ECGs with information from paired transthoracic echocardiography reports, aimed at label-efficient screening for structural heart disease (SHD) on wearable and portable single-lead ECG devices. A 7-layer 1D-CNN ECG encoder and a RoBERTa-based text encoder are contrastively pretrained (CLIP-style) on 194,551 ECG-echo report pairs from 77,378 adults in the Yale New Haven Health System, then the ECG encoder is fine-tuned on a temporally-distinct cohort to detect reduced LVEF, diastolic dysfunction, and a composite SHD label. Matches a randomly-initialized CNN at full training-data volume but substantially outperforms it in label-scarce regimes (e.g. with only 0.5% of labeled data).
Model ID: 0066
·
Subject Count: 77,378
Fully automated deep learning workflow for characterizing cardiac mechanics from balanced steady-state free-precession (bSSFP) cine cardiac MRI. It decouples two convolutional networks—a segmentation net (CarSON) and a 3D motion-estimation net (CarMEN)—to derive left- and right-ventricular volumes plus global and regional myocardial strain and strain rate without manual tracing. Trained and validated on healthy and cardiovascular-disease subjects and shown to be robust across MRI vendors, with excellent intra-scanner repeatability for strain. Developed at Massachusetts General Hospital and the Harvard-MIT Division of Health Sciences and Technology.
Model ID: 0056
·
Subject Count: 150
Vision-language model that jointly embeds a cardiac MRI study, treated as video, with the impression section of its clinical report. Combines a video encoder over cine/LGE frame sequences with a Bio+ClinicalBERT text encoder using CLIP-style contrastive training. Supports zero-shot and few-shot classification of cardiomyopathies, amyloidosis, and LV dysfunction, plus image/report retrieval and structured report drafting. Trained on a private, single-institution corpus of roughly 11,000-14,000 CMR study-report pairs from Cleveland Clinic and Case Western.
Model ID: 0007
·
Subject Count: 12,500
Vision-language foundation model fine-tuned from CLIP on more than one million private echocardiogram video-report pairs, enabling zero-shot cardiac function assessment, device identification, and image/text retrieval without task-specific training. Combines a ConvNeXt-Base video encoder with a GPT-2-style text encoder under contrastive pretraining. Training data is private, but model weights and code are public. Developed by Cedars-Sinai's Ouyang lab.
Model ID: 0035
End-to-end pipeline for apical-4-chamber echocardiogram videos that segments the left ventricle, estimates ejection fraction on a beat-to-beat basis, and classifies cardiomyopathy with reduced ejection fraction. Combines a DeepLabV3-ResNet50 segmentation model with a 3D CNN (R2+1D/R3D/MC3) initialized on the Kinetics-400 video dataset. Trained on the public EchoNet-Dynamic dataset released alongside it, and one of the most widely reused open echocardiography models since its 2020 Nature publication. Developed by Stanford University.
Model ID: 0036
·
Subject Count: 10,030
CLIP-style model that aligns 12-lead ECG signals with free-text echocardiography reports for zero-shot detection of structural heart disease directly from an ECG. Extends the MERL framework, and was trained on 45,016 paired ECG-echo reports from two Hong Kong hospitals, with external validation on the public EchoNext dataset from Columbia University. Developed by researchers at the University of Hong Kong and Imperial College London; described in a 2025 medRxiv preprint.
Model ID: 0045
View-agnostic, multi-task model that performs 39 different echocardiographic reporting tasks - covering chamber size and function, valve disease, and more - from any combination of views, aggregating clip-level predictions up to the study level. Combines a ConvNeXt-Tiny frame encoder with a temporal Transformer and separate output heads per task. Trained on private Yale-New Haven Health System echo videos and published in JAMA in 2025 by Yale's CarDS Lab.
Model ID: 0043
·
Subject Count: 24,405