1 public weights
Open-source, fully automated framework for end-to-end aortic analysis from CT angiography (CTA), built on top of TotalSegmentator baseline segmentations with additional refinement. AortaExplorer extracts established biomarkers such as diameters across anatomical segments defined by the European Society of Cardiology, and introduces new metrics including aortic tortuosity. Diameter measurements were validated against expert manual readings in more than 10,000 CTA scans from Danish population cohorts, and the tortuosity index's increase with age is consistent with prior literature; the tool reduces per-case analysis time from about 15 minutes to under 5 minutes.
Model ID: 0151
Machine-learning surrogate model for estimating pulsatile hemodynamic fields (velocity, pressure) in coronary arteries from a steady-state computational fluid dynamics (CFD) prior, avoiding the high computational cost of full pulsatile CFD. The model, a neural field conditioned on hemodynamic boundary conditions, is discretisation-independent and can be parametrised with message-passing or self-attention layers by relaxing point-wise action to permutation-equivariance. Evaluated on 74 stenotic coronary arteries from coronary CT angiography (CCTA) with patient-specific pulsatile CFD as ground truth, the model produced accurate, discretisation-independent estimates of pulsatile velocity and pressure fields.
Model ID: 0146
·
Subject Count: 74