8 models found
·
5 public code
·
1 public weights
nnU-Net-based pipeline for automated detection and sub-classification of acute thoracic aortic dissection (AD) on heterogeneous CT imaging, formulated as a semantic segmentation task rather than direct image classification. The model segments the false lumen (ascending and descending) and the dissection membrane -- along with optional indirect signs such as hemopericardium, aortic wall hematoma, and supra-aortic branch dissection -- and a patient is classified as AD-positive if at least two of the three primary segmented regions exceed a volume threshold tuned via Youden's index; the same pipeline additionally flags Stanford type A dissections. Trained on 157 heterogeneous internal CT studies (not restricted to a single contrast protocol) from Mannheim University Medical Centre and evaluated on an internal held-out test set as well as public external datasets (ImageTBAD and AVT), the model reached an AUROC of 98.7% internally and 97.0% externally, and correctly flagged 93.3% of dissection cases that had not been clinically suspected before imaging. The authors state the trained network will be made publicly available as a non-medical device for further scientific research.
Model ID: 0113
·
Subject Count: 263
Coronary artery calcium (CAC) scoring model that transfers a CNN trained for calcium scoring on non-contrast CT (NCCT) to coronary CT angiography (CCTA), where iodinated contrast otherwise confounds calcium detection and large annotated CCTA training sets are scarce. The CAC-scoring CNN is split into a feature generator and a classifier; the feature generator is trained on the NCCT source domain and adapted to the CCTA target domain via adversarial learning combined with a maximum-mean-discrepancy loss, while the source-domain classifier is reused unchanged for the target domain. Builds directly on the authors' earlier non-contrast CT calcium-scoring network.
Model ID: 0106
End-to-end deep learning framework that predicts the procedural outcome of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions directly from preprocedural coronary CT angiography, aiming to replace slower manual scoring systems (J-CTO, CT-RECTOR, KCCT). The pipeline first segments the coronary artery tree (Patch-UCTNet), detects candidate CTO lesions along the delineated vessel, extracts pathological lesion features with a Swin Transformer, and classifies two outcomes: successful guidewire crossing within 30 minutes and overall PCI success. In the original study, the model completed reconstruction and analysis 85% faster than manual scores (73.7s vs. 418-467s) and was more accurate than the manual CT-RECTOR, KCCT, and J-CTO_CCTA_ scores, reaching an AUROC of 0.97 on the internal test set and 0.96 on an independent external validation cohort (186 patients, 189 CTO lesions).
Model ID: 0107
Two-stage convolutional neural network that automatically detects and anatomically labels coronary artery, thoracic aorta, and cardiac-valve calcifications in low-dose chest CT acquired for lung-cancer screening. A first CNN with a large receptive field (via dilated convolutions) identifies and anatomically labels candidate calcifications; a second CNN filters true positives from the candidates. Trained and evaluated on 1,744 CT scans from the National Lung Screening Trial (NLST), reaching an F1 of 0.89 (soft-filter reconstructions) / 0.84 (sharp-filter reconstructions) for coronary artery calcifications and a linearly-weighted kappa of 0.90-0.91 for per-subject cardiovascular risk categorization versus the manual reference standard.
Model ID: 0102
·
Subject Count: 1,744
Deep learning pipeline for detection and quantification of abdominal aortic aneurysm (AAA) -- a typically asymptomatic condition often missed incidentally by radiologists -- from abdominal-pelvic CT. A modified 3D U-Net segments the aorta on both contrast and non-contrast CT volumes with a variable number of images, after which an ellipse-fitting post-processing step measures the aortic cross-sectional diameter along the vessel to detect aneurysmal dilation. Trained and validated on 321 abdominal-pelvic CT examinations from Massachusetts General Hospital, the model reached a sensitivity/specificity of 0.91/0.95 on the primary validation set, and 0.85/1.0 on a separate 57-exam generalization test set with different patient demographics and acquisition characteristics; the authors report that DeepAAA exceeded literature-reported radiologist performance for incidental AAA detection.
Model ID: 0114
·
Subject Count: 321
U-Net-variant segmentation model that identifies and quantifies coronary artery calcium (CAC) directly from routine non-gated, non-contrast chest CT scans -- the kind ordered for lung-cancer screening or unrelated indications rather than a dedicated cardiac scan -- so that the tens of millions of such scans performed annually can be opportunistically screened for cardiovascular risk without any extra imaging. Predicted calcium masks are combined with the CT's Hounsfield units to compute an Agatston-equivalent score. Trained on 446 expert-segmented scans from 98 medical centers across the U.S. Department of Veterans Affairs national health system (capturing substantial heterogeneity in scanners and protocols) and benchmarked against 795 patients with a paired same-year gated CAC study: nongated AI-CAC differentiates zero-vs-nonzero and <100-vs->=100 Agatston categories with 89.4% (F1 0.93) and 87.3% (F1 0.89) accuracy respectively, and its score stratifies 10-year all-cause mortality (CAC 0 vs. >400: 25.4% vs. 60.2%, hazard ratio 3.49) and composite stroke/MI/death risk (33.5% vs. 63.8%, hazard ratio 3.00). In a simulated opportunistic-screening run across 8,052 low-dose CT scans, cardiologists confirmed 99.2% of patients flagged with AI-CAC >400 would benefit from lipid-lowering therapy. Code and trained model weights are both public under an MIT license.
Model ID: 0099
Vision Transformer-based classifier that detects abnormal left-ventricular ejection fraction (LVEF < 50%) directly from static, non-gated, non-contrast chest CT scans -- an imaging modality ordered for unrelated indications (lung cancer screening, pulmonary embolism, trauma) in over 80 million US exams a year -- as a form of opportunistic heart-failure screening. Fine-tunes the encoder of the CT-ViT (GenerateCT) framework, with separate spatial (axial-plane) and z-axis (slice-wise) self-attention blocks, on 3D CT volumes paired with echocardiogram-derived LVEF labels from 25,948 Columbia University studies; reaches an AUROC of 0.786 on a held-out test set and 0.762 on external validation at Weill Cornell Medicine, clearly outperforming demographic/diagnosis-code-only baselines (Random Forest, XGBoost, AUROC 0.54-0.61). On a radiologist-comparison subset, the model's weighted F1 (0.80-0.81) exceeded two board-certified thoracic radiologists (0.62-0.80) at a small fraction of the interpretation time. Grad-CAM saliency maps highlighted clinically sensible correlates of reduced LVEF (cardiomegaly, dilated superior vena cava, calcified ascending aorta, pacemaker hardware, pulmonary edema). No public code or model weights have been released.
Model ID: 0095
·
Subject Count: 19,410
Multi-instance-learning (MIL) model for detecting >=50% coronary stenosis directly from curved multiplanar reformation (CMR) images generated during routine coronary CT angiography (CCTA) reads, without requiring slice-level annotations. A multi-range Hounsfield-unit preprocessing pipeline (Sobel edge detection across five attenuation windows) highlights plaque and vessel-wall structures, which a VGG16-based encoder with positional encoding and multi-head attention aggregates across each patient's 'bag' of up to 36 CMR slices per artery to give an interpretable, attention-weighted patient-level prediction. Trained and five-fold cross-validated on 900 real-world CCTA cases (776 LAD / 694 RCA / 600 LCX) from Sahlgrenska University Hospital, reaching AUCs of 0.91-0.92 across the three major coronary arteries. Code (preprocessing + MIL training pipeline) is public; the clinical CMR dataset and trained weights are not released.
Model ID: 0083
·
Subject Count: 900