27 models found
·
27 public code
·
20 public weights
Open-source, fully automated framework for end-to-end aortic analysis from CT angiography (CTA), built on top of TotalSegmentator baseline segmentations with additional refinement. AortaExplorer extracts established biomarkers such as diameters across anatomical segments defined by the European Society of Cardiology, and introduces new metrics including aortic tortuosity. Diameter measurements were validated against expert manual readings in more than 10,000 CTA scans from Danish population cohorts, and the tortuosity index's increase with age is consistent with prior literature; the tool reduces per-case analysis time from about 15 minutes to under 5 minutes.
Model ID: 0151
Machine-learning surrogate model for estimating pulsatile hemodynamic fields (velocity, pressure) in coronary arteries from a steady-state computational fluid dynamics (CFD) prior, avoiding the high computational cost of full pulsatile CFD. The model, a neural field conditioned on hemodynamic boundary conditions, is discretisation-independent and can be parametrised with message-passing or self-attention layers by relaxing point-wise action to permutation-equivariance. Evaluated on 74 stenotic coronary arteries from coronary CT angiography (CCTA) with patient-specific pulsatile CFD as ground truth, the model produced accurate, discretisation-independent estimates of pulsatile velocity and pressure fields.
Model ID: 0146
·
Subject Count: 74
Self-supervised multi-encoder autoencoder (MEAE) that separates heartbeat-related source signals from noisy photoplethysmogram (PPG) via blind source separation, improving heart-rate detection without requiring any pre-processing or manual data selection. Trained entirely on PPG signals from a large open polysomnography database (with no cleaning or curation), the model is then applied to a noisy real-world PPG dataset collected during daily activities of 9 subjects and a surgical dataset of 4,681 patients; the extracted heartbeat-related source signal significantly improves heart-rate detection accuracy compared with using the raw PPG signal directly.
Model ID: 0162
Deep learning strategy for cost-effective, comprehensive cardiac screening from ECG alone, by transferring domain-specific structural information from cardiac magnetic resonance (CMR) imaging into ECG representations. Combines multimodal contrastive learning with masked data modelling during pretraining on paired ECG-CMR data, then uses only ECG at inference. On 40,044 UK Biobank subjects, the multimodal pretraining improved subject-specific CVD risk prediction by up to 12.19% and cardiac phenotype prediction by up to 27.59% versus ECG-only baselines, with learned ECG representations shown to incorporate information from CMR regions of interest.
Model ID: 0140
·
Subject Count: 40,044
Self-supervised deep learning model that extracts cardiovascular-risk-relevant patterns from multimodal polysomnography (PSG) signals -- EEG, ECG, and respiratory signals -- without relying on manual sleep-stage annotations. Trained on 4,398 participants, the model derives 'projection scores' by contrasting embeddings from individuals with and without cardiovascular disease (CVD) outcomes. Externally validated in an independent cohort of 1,093 participants, ECG-derived projection scores were predictive of prevalent and incident cardiac conditions (particularly CVD mortality), and combining projection scores with the Framingham Risk Score consistently improved prediction (AUC 0.607-0.965 internally, 0.710-0.807 externally across most outcomes).
Model ID: 0147
·
Subject Count: 4,398
Regression-based convolutional neural network that directly estimates the heart-rate-corrected QT interval (QTc) from a 12-lead ECG, aiming to improve on automated QTc measurements from commercial ECG systems, which often diverge from expert readings. QTcNet was trained on 120,300 algorithm-labeled ECGs from an internal hospital cohort and the public MIMIC-IV database (after correcting for a vendor-specific measurement bias), and evaluated against expert QTc measurements in three independent external cohorts (PTB Diagnostic ECG Database, QTcMS, and ECGRDVQ). It roughly halved the mean absolute error compared with standard ECG analysis software (from 23.4ms to 13.4ms across external validation cohorts), with explainability analysis confirming the model focuses on physiologically plausible QRS-onset and T-offset regions.
Model ID: 0135
Deep-learning model that estimates a patient's 10-year risk of major adverse cardiovascular events (MACE) directly from a single routine chest radiograph (CXR), intended as an opportunistic risk-assessment tool when the inputs needed for the standard ASCVD risk calculator (lipids, blood pressure, smoking status, etc.) are missing. A 2D convolutional network takes the CXR image alone as input and outputs a continuous 10-year MACE risk estimate. Developed on 147,801 CXRs from 40,718 participants in the PLCO cancer-screening trial and externally validated in 8,869 outpatients with unknown ASCVD risk and 2,132 with known risk at Mass General Brigham, CXR CVD-Risk identified people at elevated MACE risk (adjusted hazard ratio 1.73 for a >=7.5% predicted risk) and provided added discrimination beyond the traditional ASCVD score.
Model ID: 0125
·
Subject Count: 40,718
Open-source, vendor-agnostic deep learning pipeline that retrospectively measures left ventricular global longitudinal strain (GLS) from routine apical-4-chamber echocardiography B-mode video, without requiring speckle-tracking software or manual tracing. The pipeline reuses EchoNet-Dynamic's LV semantic-segmentation network to trace the LV endocardial border frame-by-frame, then measures the frame-to-frame change in traced myocardial length across the cardiac cycle to derive GLS. In external validation against a large 3D-echocardiography-derived GLS dataset and a prospective two-sonographer, two-vendor repeated-measures study, the automated strain measurement showed lower inter- and intra-measurement variability than human readers and moderate agreement with reference speckle-tracking strain (ICC 0.58), while being robust to image-quality differences and vendor.
Model ID: 0121
·
Subject Count: 10,030
Pediatric-specific extension of EchoNet-Dynamic: a video-based deep learning model that segments the left ventricle and estimates ejection fraction (EF) from apical-4-chamber (A4C) and parasternal short-axis (PSAX) pediatric echocardiogram clips. Because adult-trained echo models generalize poorly to children (who vary widely in heart size, rate, and image quality), EchoNet-Peds was trained from scratch on a dedicated pediatric video dataset. It segments the LV with a Dice similarity coefficient of 0.89 in both views, estimates EF with a mean absolute error of 3.66%, and identifies pediatric systolic dysfunction with an AUC of 0.95, significantly outperforming an adult-trained model applied to the same pediatric data.
Model ID: 0126
·
Subject Count: 1,923
ECG-guided photoplethysmography (PPG) foundation model pretrained on over 100,000 hours of synchronized PPG-ECG recordings from 58,796 subjects across five clinical and wearable sources, using a CLIP-style contrastive alignment framework so the PPG encoder inherits physiologically grounded structure from paired ECG. Achieves state-of-the-art performance on 13 of 15 conventional physiological-analysis tasks across eight datasets, and shows meaningful discriminative capability (AUC >= 0.70) for 307 ICD-10-coded phenotypes across 16 phecode chapters, including many non-cardiovascular conditions.
Model ID: 0067
·
Subject Count: 58,796
Foundation vision-language model for cardiac MRI that learns pathophysiological visual representations directly from the natural-language radiology reports accompanying each scan, rather than from hand-labeled targets. A Multi-scale Vision Transformer (MViT, Kinetics-400-initialized) video encoder for cine CMR sequences is contrastively pretrained (InfoNCE) against a PubMed-pretrained BERT text encoder over 19,041 multi-institutional CMR studies. The frozen vision encoder transfers with strong performance to left-ventricular ejection-fraction regression (MAE 3.34% on a UK Biobank hold-out of ~4,259-45,623 participants) and detecting HFrEF (LVEF<40%, AUC 0.880), and the paper reports emergent zero-/few-shot performance across 39 cardiac and non-cardiac conditions including cardiac amyloidosis and hypertrophic cardiomyopathy. Code and pretrained MViT encoder weights are both released (Hugging Face, CC BY-NC 4.0).
Model ID: 0093
Multimodal cardiac-sensing foundation model pretrained with generative masked pretraining on ECG, PPG, and paired clinical/machine-generated text reports from roughly 1.7 million individuals across three large-scale critical-care and outpatient ECG datasets. A channel-embedding scheme lets the same model accept any combination of 12-lead ECG, single-lead/wearable ECG, and PPG. The resulting embeddings transfer to diagnostic classification, demographic recognition, vital-sign measurement, clinical-outcome prediction, and ECG question answering. Pretrained weights require a signed academic-access agreement rather than an open download.
Model ID: 0058
·
Subject Count: 161,352
Multi-view foundation model for coronary angiography trained with video-text contrastive learning on 203,808 angiography videos from 28,117 patients across 32,473 studies at the Montreal Heart Institute, externally validated on 4,249 studies from UCSF. Integrates multiple angiographic projections with attention-based pooling for study-level assessment spanning diagnostic, prognostic, and disease-progression tasks: significant-stenosis detection (AUROC 0.888 internal / 0.89 external), stenosis-percentage estimation (MAE 13.6% vs. 19.0% for clinical reports), chronic total occlusion, intracoronary thrombus, and coronary calcification detection. Transfer learning further enables one-year MACE prediction (AUROC 0.79) and LVEF estimation (MAE 7.3%) from the same angiography embeddings, with a mean in-hospital inference time of 4.2 seconds.
Model ID: 0075
·
Subject Count: 28,117
AI-driven pipeline for quantitative coronary-stenosis assessment from routine DICOM coronary angiography videos, combining vessel tracking with a video Swin3D transformer trained and validated on 182,418 angiography videos spanning 5 years at the Montreal Heart Institute. Achieves a mean absolute error of 20.15% and a classification AUROC of 0.8294 for stenosis-percentage prediction against cardiologist assessment, with lower inter-rater variability than two expert interventional cardiologists, and can be fine-tuned to quantitative coronary angiography (QCA) data for even lower error (MAE 7.75%).
Model ID: 0072
Framework for training an echocardiography left-ventricle segmentation model purely by data-free knowledge distillation: a ConvLSTM-based student network learns to reproduce the masks produced by an EchoNet-Dynamic (DeepLabV3-ResNet50) teacher on entirely synthetic echo videos, with no real labeled data or even real videos required. Achieves state-of-the-art results identifying end-diastolic/end-systolic frames, reaching segmentation quality close to real-data training with substantially fewer weights; also introduces a human-annotation-free evaluation method using a large auxiliary model.
Model ID: 0065
Adapts the Segment Anything Model (SAM) to echocardiography video segmentation by giving it a space-time memory that carries both spatial and temporal cues, so that only the first frame of a video needs an external point prompt and every subsequent frame is segmented from a propagated memory prompt instead. A memory reinforcement mechanism uses each frame's predicted mask to suppress speckle-noise features before they are written back into memory, addressing a key failure mode of naively adapting video object segmentation (e.g. XMem) to noisy ultrasound. Built on SAMUS (an ultrasound-adapted SAM) with a frozen SAM backbone and only the image-encoder adapter layers trained. On the semi-supervised CAMUS and EchoNet-Dynamic benchmarks (only end-diastole/end-systole frames labeled), MemSAM reaches 93.3% and 92.8% mean Dice respectively, outperforming UNet, SwinUNet, H2Former, and prior medical-SAM adaptations (MedSAM, MSA, SAMed, SonoSAM, SAMUS) with far fewer prompts, and derives LVEF (via Simpson's biplane method of disks) with a Pearson correlation of 78.9% against ground truth on CAMUS. Training/inference code is public (MIT license); only the starting SAM ViT-B checkpoint is linked for download, not a separately released fine-tuned MemSAM checkpoint.
Model ID: 0098
·
Subject Count: 10,530
Multimodal cardiac MRI foundation model that fuses 3D+T cine CMR (short-axis and long-axis views) with tabular patient health records (demographics, metabolic, and lifestyle factors) from 42,000 UK Biobank participants. Two-stage self-supervised pretraining -- masked-image reconstruction, then imaging-tabular contrastive alignment -- produces representations that transfer to whole-heart segmentation, cardiac phenotype/physiological-feature regression, and cardiac/metabolic disease classification within one unified framework.
Model ID: 0062
·
Subject Count: 74,916
Video-based deep learning model that estimates 14 common blood biomarkers and laboratory values—including hemoglobin (anemia), B-type natriuretic peptide (BNP), troponin I, and blood urea nitrogen (BUN)—directly from apical-4-chamber echocardiogram videos. Built on a spatiotemporal convolutional network (R(2+1)D-style) with residual connections that produces beat-by-beat estimates for both regression and abnormality classification. Trained on over 70,000 echocardiograms from Stanford Healthcare and externally validated at Cedars-Sinai, reaching AUCs around 0.80–0.86 for detecting anemia and elevated BNP. Developed by the Ouyang and Zou labs at Stanford University and Cedars-Sinai.
Model ID: 0052
Foundation model for cine cardiac MRI, self-supervised via masked autoencoding on nearly 75,000 UK Biobank scans. Uses a Vision Transformer with a convolutional stem, unified across long-axis and short-axis views. Fine-tuned checkpoints are released for ventricle and myocardium segmentation, ejection-fraction regression, cardiovascular disease classification, and landmark localization across several public benchmark datasets (ACDC, M&Ms, M&Ms2, EMIDEC, and others).
Model ID: 0003
·
Subject Count: 74,916
1D residual neural network that predicts a patient's age directly from a 12-lead ECG; the gap between this predicted 'ECG age' and true chronological age is used as a biomarker of cardiovascular risk and mortality. Trained on the CODE-15% Brazilian ECG dataset, with the original R² of 0.71 later reproduced (R² = 0.70) in an independent German validation cohort. Developed by researchers at Uppsala University and UFMG.
Model ID: 0011
Vision-language foundation model fine-tuned from CLIP on more than one million private echocardiogram video-report pairs, enabling zero-shot cardiac function assessment, device identification, and image/text retrieval without task-specific training. Combines a ConvNeXt-Base video encoder with a GPT-2-style text encoder under contrastive pretraining. Training data is private, but model weights and code are public. Developed by Cedars-Sinai's Ouyang lab.
Model ID: 0035
Echocardiography foundation model trained with a latent-predictive (V-JEPA2-style) self-supervised objective rather than pixel reconstruction, pretrained on 18 million echocardiograms from 300,000 patients drawn from the public MIMIC-IV-ECHO dataset plus a private multi-site archive - reportedly the largest echo pretraining corpus assembled to date. With a frozen backbone and only lightweight added layers, it outperforms prior echo foundation models by roughly 20% on ejection-fraction estimation and 17% on right-ventricular pressure estimation, reaches strong view-classification accuracy using just 1% of labels, and transfers zero-shot to pediatric echo better than fully fine-tuned baselines. Developed by the University of Toronto's Bo Wang Lab.
Model ID: 0038
Predicts a patient's age from echocardiogram videos across four standard views (PLAX, A2C, A4C, and subcostal), trained on a private multi-site cohort of over 2.6 million videos from more than 166,000 studies across roughly 90,000 patients. The gap between this AI-predicted age and true chronological age is studied as a marker of accelerated or delayed cardiovascular aging and its relationship to all-cause mortality. Uses a 3D CNN (R(2+1)D) with a separate pretrained model per view. Developed by Cedars-Sinai Medical Center and Stanford's Ouyang lab.
Model ID: 0034
·
Subject Count: 90,738
End-to-end pipeline for apical-4-chamber echocardiogram videos that segments the left ventricle, estimates ejection fraction on a beat-to-beat basis, and classifies cardiomyopathy with reduced ejection fraction. Combines a DeepLabV3-ResNet50 segmentation model with a 3D CNN (R2+1D/R3D/MC3) initialized on the Kinetics-400 video dataset. Trained on the public EchoNet-Dynamic dataset released alongside it, and one of the most widely reused open echocardiography models since its 2020 Nature publication. Developed by Stanford University.
Model ID: 0036
·
Subject Count: 10,030
Measures interventricular septum thickness, LV internal diameter, and posterior wall thickness from PLAX echocardiogram videos, then classifies the underlying cause of left ventricular hypertrophy as either cardiac amyloidosis or hypertrophic cardiomyopathy. Combines an atrous-convolution 2D CNN for wall-thickness segmentation with a 3D residual CNN for etiology classification. Trained on 28,201 videos across Stanford, Cedars-Sinai, and the Unity Imaging Collaborative. Developed by Stanford University.
Model ID: 0040
Automates standard echocardiographic measurements from video, pairing a measurement model with a companion segmentation component. Developed by Stanford and Cedars-Sinai's Ouyang lab; public documentation on the exact measurements covered, training data, and validation performance is limited compared to other EchoNet-family models.
Model ID: 0041
View-agnostic, multi-task model that performs 39 different echocardiographic reporting tasks - covering chamber size and function, valve disease, and more - from any combination of views, aggregating clip-level predictions up to the study level. Combines a ConvNeXt-Tiny frame encoder with a temporal Transformer and separate output heads per task. Trained on private Yale-New Haven Health System echo videos and published in JAMA in 2025 by Yale's CarDS Lab.
Model ID: 0043
·
Subject Count: 24,405