4 models found
·
4 public code
·
4 public weights
Reinforcement-learning-based unsupervised domain adaptation framework for spatio-temporal (2D+time) echocardiography segmentation, extending the authors' earlier RL4Seg work to full-length video sequences. RL4Seg3D uses a sliding-window approach supporting high-resolution, full-sized inputs, and fuses multiple reward mechanisms to improve segmentation reliability without requiring additional expert annotations in the target domain. Trained and evaluated on a large dataset of over 30,000 echocardiography videos, it outperforms baselines and foundation models on overall segmentation accuracy as well as echocardiography-specific metrics including anatomical/temporal validity and mitral-valve-commissure landmark precision, and supports test-time optimization via calibrated uncertainty estimates.
Model ID: 0159
The original U-Net baseline segmentation network introduced alongside the CAMUS (Cardiac Acquisitions for Multi-structure Ultrasound Segmentation) dataset, one of the largest fully open-access, expert-annotated 2D echocardiography benchmarks. The network segments the left ventricle endocardium (LVEndo), left ventricle epicardium/myocardium (LVEpi), and left atrium (LA) from apical 2-chamber and 4-chamber echo views at end-diastole (ED) and end-systole (ES). In the original ten-fold cross-validation benchmark comparing U-Net, U-Net++, Stacked Hourglass, Anatomically Constrained Neural Networks, and classical methods, the U-Net variant (18M parameters) achieved the best overall accuracy, reaching Dice scores of 0.939 (ED) / 0.916 (ES) for LVEndo and 0.954 (ED) / 0.945 (ES) for LVEpi, approaching inter-observer variability. A pretrained checkpoint of this baseline U-Net is distributed via the University of Sherbrooke's vitalab CASTOR project as part of a broader library for building anatomically-constrained cardiac segmentation pipelines.
Model ID: 0115
·
Subject Count: 500
Echocardiography foundation model trained with a latent-predictive (V-JEPA2-style) self-supervised objective rather than pixel reconstruction, pretrained on 18 million echocardiograms from 300,000 patients drawn from the public MIMIC-IV-ECHO dataset plus a private multi-site archive - reportedly the largest echo pretraining corpus assembled to date. With a frozen backbone and only lightweight added layers, it outperforms prior echo foundation models by roughly 20% on ejection-fraction estimation and 17% on right-ventricular pressure estimation, reaches strong view-classification accuracy using just 1% of labels, and transfers zero-shot to pediatric echo better than fully fine-tuned baselines. Developed by the University of Toronto's Bo Wang Lab.
Model ID: 0038
End-to-end pipeline for apical-4-chamber echocardiogram videos that segments the left ventricle, estimates ejection fraction on a beat-to-beat basis, and classifies cardiomyopathy with reduced ejection fraction. Combines a DeepLabV3-ResNet50 segmentation model with a 3D CNN (R2+1D/R3D/MC3) initialized on the Kinetics-400 video dataset. Trained on the public EchoNet-Dynamic dataset released alongside it, and one of the most widely reused open echocardiography models since its 2020 Nature publication. Developed by Stanford University.
Model ID: 0036
·
Subject Count: 10,030