3 models found
·
1 public code
·
0 public weights
Self-supervised contrastive learning technique for classifying carotid plaques from ultrasound images under label scarcity. In a pretext task, a triplet network takes three augmented views (strong- and weak-augmentation) of each image and promotes their similarity from both feature- and instance-level perspectives to learn effective plaque representations; the resulting encoder is then fine-tuned on labeled ultrasound images for the downstream classification task. FeaCL achieved 83.4% classification accuracy using only 30% of the training data -- a 16.3% improvement over the same network trained without the self-supervised pretext task.
Model ID: 0156
nnU-Net-based pipeline for automated detection and sub-classification of acute thoracic aortic dissection (AD) on heterogeneous CT imaging, formulated as a semantic segmentation task rather than direct image classification. The model segments the false lumen (ascending and descending) and the dissection membrane -- along with optional indirect signs such as hemopericardium, aortic wall hematoma, and supra-aortic branch dissection -- and a patient is classified as AD-positive if at least two of the three primary segmented regions exceed a volume threshold tuned via Youden's index; the same pipeline additionally flags Stanford type A dissections. Trained on 157 heterogeneous internal CT studies (not restricted to a single contrast protocol) from Mannheim University Medical Centre and evaluated on an internal held-out test set as well as public external datasets (ImageTBAD and AVT), the model reached an AUROC of 98.7% internally and 97.0% externally, and correctly flagged 93.3% of dissection cases that had not been clinically suspected before imaging. The authors state the trained network will be made publicly available as a non-medical device for further scientific research.
Model ID: 0113
·
Subject Count: 263
Deep learning pipeline for detection and quantification of abdominal aortic aneurysm (AAA) -- a typically asymptomatic condition often missed incidentally by radiologists -- from abdominal-pelvic CT. A modified 3D U-Net segments the aorta on both contrast and non-contrast CT volumes with a variable number of images, after which an ellipse-fitting post-processing step measures the aortic cross-sectional diameter along the vessel to detect aneurysmal dilation. Trained and validated on 321 abdominal-pelvic CT examinations from Massachusetts General Hospital, the model reached a sensitivity/specificity of 0.91/0.95 on the primary validation set, and 0.85/1.0 on a separate 57-exam generalization test set with different patient demographics and acquisition characteristics; the authors report that DeepAAA exceeded literature-reported radiologist performance for incidental AAA detection.
Model ID: 0114
·
Subject Count: 321