4 models found
·
2 public code
·
2 public weights
Regression-based convolutional neural network that directly estimates the heart-rate-corrected QT interval (QTc) from a 12-lead ECG, aiming to improve on automated QTc measurements from commercial ECG systems, which often diverge from expert readings. QTcNet was trained on 120,300 algorithm-labeled ECGs from an internal hospital cohort and the public MIMIC-IV database (after correcting for a vendor-specific measurement bias), and evaluated against expert QTc measurements in three independent external cohorts (PTB Diagnostic ECG Database, QTcMS, and ECGRDVQ). It roughly halved the mean absolute error compared with standard ECG analysis software (from 23.4ms to 13.4ms across external validation cohorts), with explainability analysis confirming the model focuses on physiologically plausible QRS-onset and T-offset regions.
Model ID: 0135
Multi-outcome AI-ECG risk-estimation platform that turns a single 12-lead ECG into a patient-specific survival curve, using a residual convolutional neural network trained with a discrete-time survival loss to predict not just risk but time-to-event. Beyond all-cause and cardiovascular mortality, separately fine-tuned heads predict future ventricular arrhythmia, complete heart block, atrial fibrillation, atherosclerotic cardiovascular disease, heart failure, and (in follow-up work) hypertension -- all from a single resting ECG, including in ECGs a cardiologist would read as normal. Derived on 1.16 million ECGs from 189,539 Beth Israel Deaconess Medical Center patients and externally validated across transnational cohorts in the USA, Brazil (CODE), and the UK (UK Biobank). A variational autoencoder and genome/phenome-wide association analyses were used to show the model's predictions track biologically plausible features (QRS morphology, LV structure/function, and loci linked to cardiac structure, QT interval, and biological aging). NHS trials of AIRE were planned for late 2025. No public code or model weights have been released.
Model ID: 0089
·
Subject Count: 189,539
ECG-guided photoplethysmography (PPG) foundation model pretrained on over 100,000 hours of synchronized PPG-ECG recordings from 58,796 subjects across five clinical and wearable sources, using a CLIP-style contrastive alignment framework so the PPG encoder inherits physiologically grounded structure from paired ECG. Achieves state-of-the-art performance on 13 of 15 conventional physiological-analysis tasks across eight datasets, and shows meaningful discriminative capability (AUC >= 0.70) for 307 ICD-10-coded phenotypes across 16 phecode chapters, including many non-cardiovascular conditions.
Model ID: 0067
·
Subject Count: 58,796
Self-supervised foundation model for photoplethysmography (PPG) that explicitly targets the low-signal-quality problem endemic to real-world wearable and bedside PPG, rather than assuming clean input. A Siamese ResNet (SimSiam-style) encoder is pretrained to produce similar representations for temporally-adjacent high- and low-quality PPG segments presumed to share the same underlying physiological state, with curriculum learning that gradually increases the artifact-level gap between paired segments. Pretrained on over 36 million 30-second PPG pairs drawn from more than 24,100 UCSF ICU patients, then fine-tuned and evaluated on six downstream cardiovascular-monitoring datasets/tasks (heart rate, respiratory rate, blood pressure, and atrial-fibrillation detection), where it exceeds prior state-of-the-art by roughly 75% on respiratory-rate estimation and 5% on AF detection, with performance scaling with backbone depth (ResNet152 best). Code and the pretraining dataset are not public; the pretraining data is available upon request under a UCSF-Emory data use agreement.
Model ID: 0097
·
Subject Count: 24,100