4 models found
·
4 public code
·
4 public weights
Supervised EfficientNetV2-based 12-lead ECG model trained on over 1 million ECGs from the Montreal Heart Institute to predict 77 cardiac conditions derived from American Heart Association recommendations, plus fine-tuned digital-biomarker heads for reduced LVEF, 5-year atrial-fibrillation risk, and long-QT-syndrome (LQTS) detection/genotyping. Validated on 881,403 ECGs across 11 geographically diverse cohorts (4 public, 7 private health systems), achieving AUROCs above 0.98 for the 77-condition interpretation task while being 60x smaller and 29x faster at inference than its self-supervised DeepECG-SSL counterpart, with up to 9.7x lower CO2 emissions on equivalent tasks.
Model ID: 0070
·
Subject Count: 184,210
ECG foundation model built on the xLSTM (extended LSTM) architecture: a bidirectional stack of nine alternating scalar- and matrix-memory LSTM blocks that scales linearly with sequence length, unlike the quadratic cost of transformer-based ECG models. Pretrained with SimDINOv2, a coding-rate-regularized self-distillation (DINO) objective adapted from computer vision to ECG time series, on roughly 8 million recordings from CODE, INCART, and Chapman-Shaoxing-Ningbo. Introduced alongside BenchECG, a standardized 8-dataset/10-task benchmark, on which xECG achieves the best average rank of any publicly available ECG foundation model, with particular strength on long-context tasks (30-minute ambulatory arrhythmia classification, multi-hour sleep-apnea segmentation) where transformer-based models are computationally limited.
Model ID: 0063
·
Subject Count: 45,184
Dual-encoder single-lead ECG classifier for atrial fibrillation detection that fuses a raw-signal branch with a spectrogram branch via axial attention and a Transformer. Originally developed as a graduate-course project at TU Darmstadt for the 2017 PhysioNet/CinC Challenge, and later extended in a 2023 follow-up study. Released in four sizes up to 130M parameters (S/M/L/XL), alongside a simpler CNN+LSTM variant.
Model ID: 0015
·
Subject Count: 11,000
Open ECG foundation model with 90.9M parameters, built on a wav2vec 2.0-style Transformer and pretrained on 1.25-1.5 million ECGs using a hybrid contrastive-and-generative self-supervised objective. Base pretrained weights and MIMIC-IV-ECG-finetuned downstream checkpoints are both released. Developed on the fairseq_signals framework by the University of Toronto / Vector Institute's Wang lab.
Model ID: 0020
·
Subject Count: 161,352