68 models found
·
64 public code
·
36 public weights
Adversarial deep learning model that predicts treatment effects for cardiology patients from structured electronic health record (EHR) data, aiming to forecast expected clinical outcomes of specific treatment choices given a patient's clinical status. Two autoencoders separately learn representations of patient characteristics and of the treatments given; an adversarial loss then encourages these representations to capture the correlational structure between a patient's status and the treatment received, improving downstream outcome prediction over non-adversarial baselines. Evaluated on two private cardiology EHR cohorts from a Chinese hospital, ADTEP modestly outperformed a non-adversarial ablation (DTEP) and classical baselines (logistic regression, SVM) at predicting major adverse cardiac events (MACE) after acute coronary syndrome (AUC 0.662 vs. 0.653/0.648/0.621) and at heart-failure outcome prediction.
Model ID: 0136
Complete motion-analysis workflow for the left atrium (LA) using 3D Cine MRI, combining an online-learning segmentation network with an image-registration network to compute LA displacement vector fields (DVF) and principal strains across the cardiac cycle. Validated on 10 healthy volunteers and 8 cardiovascular disease patients, Aladdin accurately tracks LA wall motion and can identify regional deformation abnormalities that may indicate focal pathology, agreeing well with 2D Cine MRI global function estimates.
Model ID: 0139
·
Subject Count: 18
Self-supervised deep learning model for coronary artery segmentation from invasive X-ray coronary angiography (ICA), designed to reduce reliance on large annotated datasets. CM-UNet combines a Contrastive Masked Autoencoder (CMAE) with a UNet backbone: an online encoder-decoder branch reconstructs masked image patches while a momentum branch produces contrastive embeddings, jointly pretraining the network on unannotated angiography images before fine-tuning on a small labeled set. Fine-tuning with only 18 annotated images (instead of 500) led to just a 15.2% drop in Dice score, versus a 46.5% drop for baseline models trained without this self-supervised pretraining -- demonstrating strong label efficiency for coronary segmentation.
Model ID: 0137
Cross-modality cardiac image segmentation model that addresses spatial-temporal confounding -- where the anatomy and imaging-modality elements of cardiac images are intertwined across space and time. DCL performs multi-dimensional causal intervention, modeling causal relationships between images and labels as well as causality along the time and space dimensions, integrating historical optimal interventions to transfer knowledge across temporal contexts. A diffusion mechanism further keeps extracted anatomical elements causally invariant across modalities. On cross-modality cardiac images (MR, CT, and ultrasound), DCL achieved a mean Dice of 0.951, outperforming other advanced segmentation methods.
Model ID: 0148
·
Subject Count: 60
Domain-Shuffle Temporal Attention Network for coronary vessel extraction from X-ray coronary angiography (XCA), trained entirely on synthetic temporal XCA data without requiring manual vessel annotations. By leveraging synthetic data generation and a domain-shuffle temporal attention mechanism, DOSTA-Net avoids the need for costly expert-labeled real angiography sequences while still learning temporally consistent vessel segmentation across frames of an XCA sequence.
Model ID: 0160
3D convolutional autoencoder that filters reverberation clutter artifacts from transthoracic echocardiography (TTE) video sequences, improving downstream measurements such as speckle-tracking strain. Built on a 3D U-Net-style encoder-decoder with an input-output skip connection to preserve fine structures and attention-gate modules to focus on cluttered regions, the network was trained on synthetic clutter simulated across six ultrasound vendors and generalized well to real in vivo artifactual sequences, substantially reducing the discrepancy between cluttered and clutter-free strain profiles while running in a fraction of a second per sequence.
Model ID: 0145
Machine-learning surrogate model for estimating pulsatile hemodynamic fields (velocity, pressure) in coronary arteries from a steady-state computational fluid dynamics (CFD) prior, avoiding the high computational cost of full pulsatile CFD. The model, a neural field conditioned on hemodynamic boundary conditions, is discretisation-independent and can be parametrised with message-passing or self-attention layers by relaxing point-wise action to permutation-equivariance. Evaluated on 74 stenotic coronary arteries from coronary CT angiography (CCTA) with patient-specific pulsatile CFD as ground truth, the model produced accurate, discretisation-independent estimates of pulsatile velocity and pressure fields.
Model ID: 0146
·
Subject Count: 74
Supervised contrastive learning framework for robust, fine-grained echocardiographic view classification across 47 clinically meaningful view types (rather than collapsing views into a few broad categories, as most prior work does). Introduces TTE47, the first publicly available benchmark with 47 fine-grained views independently annotated by three experts, enabling rigorous quantification of inter-observer agreement. A tailored contrastive loss produces a feature space that aligns more strongly with underlying anatomy than with any single annotator's labeling style, and the model outperforms cross-entropy and standard supervised-contrastive baselines on both TTE47 and the public TMED-2 benchmark (the latter without dataset-specific pretraining).
Model ID: 0150
Self-supervised contrastive learning technique for classifying carotid plaques from ultrasound images under label scarcity. In a pretext task, a triplet network takes three augmented views (strong- and weak-augmentation) of each image and promotes their similarity from both feature- and instance-level perspectives to learn effective plaque representations; the resulting encoder is then fine-tuned on labeled ultrasound images for the downstream classification task. FeaCL achieved 83.4% classification accuracy using only 30% of the training data -- a 16.3% improvement over the same network trained without the self-supervised pretext task.
Model ID: 0156
Self-supervised ECG embedding model inspired by BERT/RoBERTa from natural language processing, designed for efficient medical signal analysis. HeartBERT translates ECG signals into an intermediate synthetic 'language' via signal quantization and discretization (Lloyd-Max quantization), then trains a RoBERTa-style encoder from scratch on this text-like representation using the MIT-BIH Arrhythmia Database, PTB-XL, and European ST-T Database. The resulting embeddings are evaluated on two downstream tasks -- sleep-stage classification and heartbeat classification -- using bidirectional LSTM heads, showing particular strength when only small labeled training datasets are available.
Model ID: 0158
·
Subject Count: 18,932
Self-supervised multi-encoder autoencoder (MEAE) that separates heartbeat-related source signals from noisy photoplethysmogram (PPG) via blind source separation, improving heart-rate detection without requiring any pre-processing or manual data selection. Trained entirely on PPG signals from a large open polysomnography database (with no cleaning or curation), the model is then applied to a noisy real-world PPG dataset collected during daily activities of 9 subjects and a surgical dataset of 4,681 patients; the extracted heartbeat-related source signal significantly improves heart-rate detection accuracy compared with using the raw PPG signal directly.
Model ID: 0162
Deep learning strategy for cost-effective, comprehensive cardiac screening from ECG alone, by transferring domain-specific structural information from cardiac magnetic resonance (CMR) imaging into ECG representations. Combines multimodal contrastive learning with masked data modelling during pretraining on paired ECG-CMR data, then uses only ECG at inference. On 40,044 UK Biobank subjects, the multimodal pretraining improved subject-specific CVD risk prediction by up to 12.19% and cardiac phenotype prediction by up to 27.59% versus ECG-only baselines, with learned ECG representations shown to incorporate information from CMR regions of interest.
Model ID: 0140
·
Subject Count: 40,044
Self-supervised deep learning model that extracts cardiovascular-risk-relevant patterns from multimodal polysomnography (PSG) signals -- EEG, ECG, and respiratory signals -- without relying on manual sleep-stage annotations. Trained on 4,398 participants, the model derives 'projection scores' by contrasting embeddings from individuals with and without cardiovascular disease (CVD) outcomes. Externally validated in an independent cohort of 1,093 participants, ECG-derived projection scores were predictive of prevalent and incident cardiac conditions (particularly CVD mortality), and combining projection scores with the Framingham Risk Score consistently improved prediction (AUC 0.607-0.965 internally, 0.710-0.807 externally across most outcomes).
Model ID: 0147
·
Subject Count: 4,398
Optimized Hierarchical Fused Fuzzy Deep Reinforcement Learning model for predicting non-sinus (higher-risk) cardiac rhythms from PQRST-analyzed 12-lead ECG data. The three-stage approach combines data preprocessing, reinforcement learning, and fuzzy deep learning to classify sinus vs. non-sinus rhythms. Evaluated on a 12-lead ECG dataset of 10,646 patients, OHFFDRL achieved 94% accuracy, an AUC of 0.91, and was interpreted using SHAP, LIME, calibration curves, adversarial vulnerability analysis, and integrated gradients; TAxis (ventricular repolarization movement range) was found to be the most important distinguishing feature.
Model ID: 0157
·
Subject Count: 10,646
Prototype-based neural network for interpretable, uncertainty-aware classification of aortic stenosis (AS) severity from B-mode echocardiography videos. Rather than a black-box prediction, ProtoASNet bases its output on similarity scores between the input video and a set of learned spatio-temporal prototypes (typically highlighting valve calcification and restricted leaflet motion), and uses an abstention loss to flag ambiguous/uncertain cases for expert review. Evaluated on a private clinical dataset and the public TMED-2 dataset, it achieved balanced accuracy of 80.0% (private) and 79.7% (TMED-2), improving to 82.4% when uncertain cases are excluded.
Model ID: 0141
Reinforcement-learning-based unsupervised domain adaptation framework for spatio-temporal (2D+time) echocardiography segmentation, extending the authors' earlier RL4Seg work to full-length video sequences. RL4Seg3D uses a sliding-window approach supporting high-resolution, full-sized inputs, and fuses multiple reward mechanisms to improve segmentation reliability without requiring additional expert annotations in the target domain. Trained and evaluated on a large dataset of over 30,000 echocardiography videos, it outperforms baselines and foundation models on overall segmentation accuracy as well as echocardiography-specific metrics including anatomical/temporal validity and mitral-valve-commissure landmark precision, and supports test-time optimization via calibrated uncertainty estimates.
Model ID: 0159
Disentangled representation learning model for cardiac image analysis that factorises 2D medical images (MRI, CT) into a spatial 'anatomy factor' (a semantically meaningful multi-channel map, produced by a U-Net-style anatomy encoder) and a non-spatial 'modality factor' (a latent vector capturing imaging-specific characteristics). This disentangled representation supports semi-supervised segmentation using only a fraction of labeled images (matching fully supervised performance), multi-task learning (e.g. jointly regressing cardiac indices), multimodal pooling of MRI and CT data, and image-to-image synthesis between modalities via latent-space arithmetic (swapping modality factors). SDNet also demonstrates that its modality factor alone can predict the input imaging modality with high accuracy.
Model ID: 0163
Self-supervised learning (SSL) model that identifies chronically stressed mother-fetus dyads from raw maternal abdominal ECG (aECG), which contains both maternal and fetal cardiac signals. Built on a self-supervised representation-learning approach originally developed for ECG-based emotion recognition, the model is pretrained on public ECG datasets and evaluated on a cohort of pregnant women with chronic stress exposure validated by psychological inventory, maternal hair cortisol, and the fetal stress index (FSI). Using maternal ECG alone with the publicly pretrained model, it detected the chronic-stress-exposure group with AUROC 0.982 and predicted psychological stress score (R2 0.943), FSI (R2 0.946), and maternal hair cortisol (R2 0.931).
Model ID: 0154
·
Subject Count: 103
Transformer-based multi-view multiple-instance learning (MIL) framework for patient-level coronary stenosis classification from multi-view invasive coronary angiography. Rather than requiring expensive view-level stenosis annotations, SegmentMIL is trained end-to-end on real-world clinical data using only patient-level labels already present in hospital systems, and jointly predicts stenosis presence while localizing the affected artery (left/right) and segment. It captures temporal dynamics and dependencies across the multiple angiographic views per patient (which prior view-level models ignore), and outperforms both single-view models and classical MIL baselines on internal and external clinical evaluations.
Model ID: 0155
·
Subject Count: 2,003
Real-time deep-learning model that fuses serial 12-lead ECG waveforms with sequential vital signs and routinely available clinical data to predict hospital admission early during emergency department (ED) encounters with cardiac presentations (chest pain, dyspnea, syncope, presyncope). Developed and validated on the public MIMIC-IV, MIMIC-IV-ED, and MIMIC-IV-ECG databases (n=30,421 ED stays with >=1 ECG; n=11,273 with >=2 ECGs), the model improves on baseline tabular (random forest) and ECG-only models by leveraging how a patient's risk evolves with successive ECGs during the visit, addressing a key limitation of single-time-point risk scores.
Model ID: 0149
·
Subject Count: 161,352
Self-supervised representation-learning method for 12-lead ECG signals, designed to reduce reliance on large labeled datasets for downstream ECG classification. TSSL exploits two structural properties of ECG data: temporally, it encourages stable representations for the same individual across time while keeping different leads distinguishable; spatially, it enforces consistency in the relationships between signals and their representations across the different leads of a single recording. Evaluated on three public ECG datasets (CPSC2018, Chapman, PTB-XL), TSSL-pretrained models approached the performance of fully supervised training while using only about 10% of the labeled data.
Model ID: 0138
·
Subject Count: 64,037
Automatic coronary artery segmentation pipeline for coronary CT angiography (CCTA). A 2D DenseNet classifier first screens out CT slices that don't contain coronary artery, then a 3D-UNet -- enhanced with dense blocks in the encoder for richer feature extraction and residual, feature-rectifying blocks in the decoder -- segments the coronary artery tree in the remaining slices. A Gaussian-weighted merging scheme combines overlapping 3D patch predictions, up-weighting the more reliable predictions near each patch's center. On the authors' in-house CCTA dataset, the method achieved a Dice similarity coefficient of 0.826.
Model ID: 0127
Open-source, user-guided deep learning tool for coronary artery segmentation from invasive coronary angiography (ICA), designed to improve on traditional quantitative coronary angiography (QCA) edge-detection algorithms that typically require manual correction. Rather than segmenting the whole coronary tree indiscriminately, AngioPy lets the user click a handful of ground-truth points along a specific target vessel (including side branches), and predicts a binary mask for that single artery at the chosen cardiac-cycle time-step. Evaluated against an established QCA system on angiograms from the FAME 2 trial, AngioPy achieved an average F1 score of 0.927 (internal) and 0.924 (external validation), with vessel-diameter and lesion minimal-lumen-diameter measurements showing excellent agreement with QCA (r=0.93-0.96).
Model ID: 0133
Deep learning model for multi-class 3D segmentation of the aorta and its thirteen branches from CT angiography, intended to support planning of endovascular aortic interventions. CIS-UNet combines a CNN encoder with a symmetric decoder and a novel Context-aware Shifted Window Self-Attention (CSW-SA) bottleneck block that adapts the Swin transformer's patch-merging mechanism to more efficiently capture global spatial context. Trained and evaluated via 4-fold cross-validation on the first public multi-branch aorta CTA dataset (59 patients), CIS-UNet outperformed the state-of-the-art SwinUNETR baseline, achieving a mean Dice of 0.713 vs. 0.697 and mean surface distance of 2.78mm vs. 3.39mm, while being more computationally efficient.
Model ID: 0130
·
Subject Count: 59
Two-stage deep learning pipeline that localizes premature ventricular contraction (PVC) beats directly from raw, unsegmented ECG signal, without relying on hand-crafted features or pre-existing R-peak annotations. An encoder-decoder network first localizes the R-peak of every heartbeat (normal or anomalous); the resulting R-peak positions are then passed to CardioIncNet, a 1D InceptionTime-based classifier, which delineates each beat as healthy or PVC. Evaluated with both single-dataset and cross-dataset protocols across three public ECG databases, the pipeline reached F1 scores above 0.99 (single-dataset) and 0.979 (cross-dataset) for R-peak localization, and above 0.96 and 0.85 respectively for PVC beat classification.
Model ID: 0128
·
Subject Count: 47
Open-source, vendor-agnostic deep learning pipeline that retrospectively measures left ventricular global longitudinal strain (GLS) from routine apical-4-chamber echocardiography B-mode video, without requiring speckle-tracking software or manual tracing. The pipeline reuses EchoNet-Dynamic's LV semantic-segmentation network to trace the LV endocardial border frame-by-frame, then measures the frame-to-frame change in traced myocardial length across the cardiac cycle to derive GLS. In external validation against a large 3D-echocardiography-derived GLS dataset and a prospective two-sonographer, two-vendor repeated-measures study, the automated strain measurement showed lower inter- and intra-measurement variability than human readers and moderate agreement with reference speckle-tracking strain (ICC 0.58), while being robust to image-quality differences and vendor.
Model ID: 0121
·
Subject Count: 10,030
Pediatric-specific extension of EchoNet-Dynamic: a video-based deep learning model that segments the left ventricle and estimates ejection fraction (EF) from apical-4-chamber (A4C) and parasternal short-axis (PSAX) pediatric echocardiogram clips. Because adult-trained echo models generalize poorly to children (who vary widely in heart size, rate, and image quality), EchoNet-Peds was trained from scratch on a dedicated pediatric video dataset. It segments the LV with a Dice similarity coefficient of 0.89 in both views, estimates EF with a mean absolute error of 3.66%, and identifies pediatric systolic dysfunction with an AUC of 0.95, significantly outperforming an adult-trained model applied to the same pediatric data.
Model ID: 0126
·
Subject Count: 1,923
Deep learning model that non-invasively estimates cardiac output (CO) from wearable seismocardiography (SCG), a single-lead ECG, and body mass index (BMI), as a potential alternative to invasive right heart catheterization (RHC). Parallel 1D-CNN branches extract features from the SCG and ECG waveforms, which are fused with BMI and passed through a lightweight regression head to predict CO directly. Trained and evaluated via leave-pair-out cross-validation on 73 heart-failure patients (83 RHC encounters) from an open PhysioNet dataset, the model achieved an RMSE of 1.00 L/min (22%) and Pearson correlation of 0.75 versus catheterization-derived CO, with particularly strong performance in low-output states.
Model ID: 0124
·
Subject Count: 73
Deep channel-attention network for segmenting the full coronary vessel tree from sequential X-ray coronary angiography (XCA) frames, rather than a single static image. An encoder-decoder architecture fuses temporal-spatial feature maps across the XCA sequence via skip connections, then uses channel-attention blocks in the decoder to refine features and separate thin vessel structures from complex, noisy backgrounds; a Dice loss addresses the severe foreground/background class imbalance typical of XCA. The authors report that SVS-net outperforms prior 2D and video-based baselines on both quantitative vessel-segmentation metrics and visual validation.
Model ID: 0129
·
Subject Count: 120
Explainable machine learning model that detects and localizes left ventricular (LV) scar in hypertrophic cardiomyopathy (HCM) patients directly from 12-lead ECG, as a faster and cheaper alternative to late-gadolinium-enhancement (LGE) cardiac MRI, the clinical gold standard. XplainScar first uses an HCM-specific ECG segmentation algorithm to extract morphological features (duration, amplitude, slope, energy) from the QRS complex, ST segment and T wave of each lead, then combines unsupervised and self-supervised representation learning to predict scar presence and reveal which ECG features are associated with scar location (basal, mid, or apical LV). Trained on 500 HCM patients from the Johns Hopkins HCM Registry and validated on a held-out cohort of 248 HCM patients from UCSF, it reached 88% precision, 90% sensitivity, 78% specificity and an F1-score of 89% for scar detection on the external test set, analyzing a 10-patient batch of ECGs in under one minute.
Model ID: 0123
·
Subject Count: 500
Coronary artery calcium (CAC) scoring model that transfers a CNN trained for calcium scoring on non-contrast CT (NCCT) to coronary CT angiography (CCTA), where iodinated contrast otherwise confounds calcium detection and large annotated CCTA training sets are scarce. The CAC-scoring CNN is split into a feature generator and a classifier; the feature generator is trained on the NCCT source domain and adapted to the CCTA target domain via adversarial learning combined with a maximum-mean-discrepancy loss, while the source-domain classifier is reused unchanged for the target domain. Builds directly on the authors' earlier non-contrast CT calcium-scoring network.
Model ID: 0106
End-to-end deep learning framework that predicts the procedural outcome of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions directly from preprocedural coronary CT angiography, aiming to replace slower manual scoring systems (J-CTO, CT-RECTOR, KCCT). The pipeline first segments the coronary artery tree (Patch-UCTNet), detects candidate CTO lesions along the delineated vessel, extracts pathological lesion features with a Swin Transformer, and classifies two outcomes: successful guidewire crossing within 30 minutes and overall PCI success. In the original study, the model completed reconstruction and analysis 85% faster than manual scores (73.7s vs. 418-467s) and was more accurate than the manual CT-RECTOR, KCCT, and J-CTO_CCTA_ scores, reaching an AUROC of 0.97 on the internal test set and 0.96 on an independent external validation cohort (186 patients, 189 CTO lesions).
Model ID: 0107
Clinically-informed modification of the ResNet-18 architecture for identifying occlusion myocardial infarction (OMI) -- a severe, often ST-elevation-negative heart attack caused by complete blockage of a coronary artery -- from a single 12-lead ECG. The network first learns lead-specific temporal features via 1xk temporal convolutions, then learns cross-lead spatial concordance/discordance (e.g. reciprocal ST changes) via a 12x1 spatial convolution placed after the residual blocks, with saliency maps highlighting the most relevant leads and waveform regions for explainability. Benchmarked against ResNet-18 and other CNN/random-forest baselines on a multisite real-world clinical dataset of 10,893 ECGs (OMI rate 6.5%), reaching a test AUROC of 0.889 and an average precision of 0.587, outperforming the compared models.
Model ID: 0103
·
Subject Count: 7,297
Ensemble classifier combining hand-engineered expert features with a deep convolutional neural network for classifying cardiac rhythm from a single-lead ECG recording into normal sinus rhythm, atrial fibrillation, another rhythm, or too noisy to classify. A large set of expert features (from time-, frequency-, and template-based analysis) is fed into a gradient-boosted tree classifier (AdaBoost), and its output is combined with a separate deep CNN operating directly on the raw waveform; combining both feature families measurably outperformed either alone. ENCASE won 1st place in the PhysioNet/Computing in Cardiology Challenge 2017 (single-lead AF classification) with an overall F1 score of 0.83 on the official hidden test set, and remains a widely cited example of combining classical signal-processing features with deep representations for ECG classification.
Model ID: 0117
Self-supervised learning method for carotid plaque segmentation from B-mode ultrasound images, designed to reduce the amount of expert-labeled data needed to train a segmentation network. A level-set-and-least-squares-based deformation procedure synthesizes registration image pairs from unlabeled carotid ultrasound images, and a spatial-transformer-based registration pretext task pretrains a Stacked U-Net (Su-Net) to focus on plaque-contour features before fine-tuning on a small labeled dataset for total plaque area (TPA) segmentation. Evaluated on carotid ultrasound datasets from two different institutions and countries, the method showed robust generalization when trained with only a small number of labeled images.
Model ID: 0111
Heart murmur detection model combining spectrogram-derived deep features with hand-crafted peak-interval (PI) features extracted from phonocardiogram recordings, submitted to the George B. Moody PhysioNet Challenge 2022 (team CAU_UMN) and later extended into the 'SpectroHeart' method. Peak-to-peak interval sequences and their summary statistics are combined with spectrogram representations of the PCG signal, optionally alongside patient demographic data, to classify murmur presence across multiple auscultation locations. The team's Challenge submission placed 5th of all teams on the murmur-detection task.
Model ID: 0109
·
Subject Count: 1,568
Multimodal machine learning model that flags patients at risk of transthyretin amyloid cardiomyopathy (ATTR-CM) -- a progressive, underdiagnosed disease with expanding disease-modifying treatment options -- from routinely available ECG waveforms, echocardiographic measurements, demographics, and diagnosis codes for orthopedic manifestations of amyloidosis (e.g. carpal tunnel syndrome, spinal stenosis). Developed on 799 patients with 5-fold cross-validation (AUROC 0.85) and externally validated on 422 patients at a separate site (AUROC 0.82), with consistent accuracy across Hispanic, non-Hispanic Black, and non-Hispanic White patients. In a subsequent nonrandomized, single-system, multisite clinical trial (the Cardiac Amyloidosis Discovery Trial), patients flagged by ATTRACTnet and referred for confirmatory amyloid scintigraphy were positive for ATTR-CM 48% of the time, more than 2.8x the positivity rate of historical (15.3%) and contemporary (17.0%) controls referred by usual clinical judgment (P < .001 for both). This is a proprietary clinical AI program; no public code or model weights have been released.
Model ID: 0096
·
Subject Count: 799
Foundation vision-language model for cardiac MRI that learns pathophysiological visual representations directly from the natural-language radiology reports accompanying each scan, rather than from hand-labeled targets. A Multi-scale Vision Transformer (MViT, Kinetics-400-initialized) video encoder for cine CMR sequences is contrastively pretrained (InfoNCE) against a PubMed-pretrained BERT text encoder over 19,041 multi-institutional CMR studies. The frozen vision encoder transfers with strong performance to left-ventricular ejection-fraction regression (MAE 3.34% on a UK Biobank hold-out of ~4,259-45,623 participants) and detecting HFrEF (LVEF<40%, AUC 0.880), and the paper reports emergent zero-/few-shot performance across 39 cardiac and non-cardiac conditions including cardiac amyloidosis and hypertrophic cardiomyopathy. Code and pretrained MViT encoder weights are both released (Hugging Face, CC BY-NC 4.0).
Model ID: 0093
Generalist reconstruction foundation model for accelerating cardiac MRI (CMR) acquisition, designed to recover diagnostic-quality images from highly undersampled (8x-24x) multi-coil k-space data across heterogeneous scanners, field strengths, and cardiovascular diseases. Combines a CLIP-ViT-based module for semantic/contextual understanding of the anatomy being imaged with a physics-informed data-consistency reconstruction network, trained on MMCMR-427K -- the largest public multimodal CMR k-space database to date. Intended as an upstream substrate that feeds downstream segmentation, phenotyping, and diagnosis models (e.g. automated cardiac-phenotype extraction via nnU-Net) rather than replacing them. Released by the CMRxRecon-challenge consortium; code and the underlying database are public for academic, non-commercial use, but no separately downloadable pretrained checkpoint is provided.
Model ID: 0086
·
Subject Count: 1,504
Fully automated pipeline for interpreting coronary angiograms that chains four purpose-built neural networks: (1) angiographic projection-angle identification, (2) left/right coronary artery detection, (3) arterial segment localization, and (4) stenosis-severity estimation. Trained on 13,843 angiographic studies (195,195 videos) from 11,972 adult patients at UCSF (2008-2019), with projection-angle and LCA/RCA-detection tasks each reaching precision/sensitivity/F1 at or above 90%. For predicting obstructive coronary artery disease (>=70% stenosis), CathAI reaches an AUC of 0.862 internally, 0.869 on external angiograms from the University of Ottawa Heart Institute, and 0.775 after retraining on quantitative-coronary-angiography labels from the Montreal Heart Institute core lab. No public code or model weights have been released.
Model ID: 0091
·
Subject Count: 11,972
Multi-view foundation model for coronary angiography trained with video-text contrastive learning on 203,808 angiography videos from 28,117 patients across 32,473 studies at the Montreal Heart Institute, externally validated on 4,249 studies from UCSF. Integrates multiple angiographic projections with attention-based pooling for study-level assessment spanning diagnostic, prognostic, and disease-progression tasks: significant-stenosis detection (AUROC 0.888 internal / 0.89 external), stenosis-percentage estimation (MAE 13.6% vs. 19.0% for clinical reports), chronic total occlusion, intracoronary thrombus, and coronary calcification detection. Transfer learning further enables one-year MACE prediction (AUROC 0.79) and LVEF estimation (MAE 7.3%) from the same angiography embeddings, with a mean in-hospital inference time of 4.2 seconds.
Model ID: 0075
·
Subject Count: 28,117
AI-driven pipeline for quantitative coronary-stenosis assessment from routine DICOM coronary angiography videos, combining vessel tracking with a video Swin3D transformer trained and validated on 182,418 angiography videos spanning 5 years at the Montreal Heart Institute. Achieves a mean absolute error of 20.15% and a classification AUROC of 0.8294 for stenosis-percentage prediction against cardiologist assessment, with lower inter-rater variability than two expert interventional cardiologists, and can be fine-tuned to quantitative coronary angiography (QCA) data for even lower error (MAE 7.75%).
Model ID: 0072
Multimodal large language model for ECG medical-report generation and cardiology conversational question-answering. An ECG-CoCa encoder (contrastive ECG-report pretraining in the style of OpenCLIP) is paired with a LLaVA-style vision-language architecture and an LLM backbone, fine-tuned on a purpose-built 45k-example ECG-instruction dataset (19k diagnosis examples + 25k multi-turn dialogue examples) built from five public 12-lead ECG datasets. Produces free-text diagnostic reports and supports zero-shot ECG-report retrieval classification.
Model ID: 0061
·
Subject Count: 225,389
First multimodal LLM to unify ECG time series, 12-lead ECG images, and text for grounded, clinician-aligned ECG interpretation. A dual-encoder framework (ECG-CoCa time-series encoder plus a LLaVA-style vision-language backbone) extracts complementary time-series and image features with cross-modal alignment, trained on knowledge-guided instruction data (ECG-Grounding, linking diagnoses to measurable waveform parameters such as QRS/PR intervals) plus the 1.15-million-conversation ECG-Instruct corpus. Introduces the "Grounded ECG Understanding" benchmark and improves predictive performance, explainability, and grounding over prior ECG-language models such as ECG-Chat and PULSE.
Model ID: 0069
·
Subject Count: 225,389
Multi-scale ECG-language pretraining model that aligns 12-lead ECG signals with clinical text reports at three granularities -- token, beat, and rhythm level -- rather than a single global embedding. First fine-tunes a cardiology-specialized text encoder to improve understanding of ECG report language, then trains an ECG-FM-initialized ECG encoder against it with hierarchical contrastive supervision. Outperforms prior ECG-language and self-supervised baselines including MERL, ST-MEM, and HeartLang on zero-shot classification, linear probing, and ECG report generation, with especially large gains at low label fractions. Developed at the University of Hong Kong (HKU-MedAI).
Model ID: 0082
·
Subject Count: 225,389
Multi-instance-learning (MIL) model for detecting >=50% coronary stenosis directly from curved multiplanar reformation (CMR) images generated during routine coronary CT angiography (CCTA) reads, without requiring slice-level annotations. A multi-range Hounsfield-unit preprocessing pipeline (Sobel edge detection across five attenuation windows) highlights plaque and vessel-wall structures, which a VGG16-based encoder with positional encoding and multi-head attention aggregates across each patient's 'bag' of up to 36 CMR slices per artery to give an interpretable, attention-weighted patient-level prediction. Trained and five-fold cross-validated on 900 real-world CCTA cases (776 LAD / 694 RCA / 600 LCX) from Sahlgrenska University Hospital, reaching AUCs of 0.91-0.92 across the three major coronary arteries. Code (preprocessing + MIL training pipeline) is public; the clinical CMR dataset and trained weights are not released.
Model ID: 0083
·
Subject Count: 900
Adapts the Segment Anything Model (SAM) to echocardiography video segmentation by giving it a space-time memory that carries both spatial and temporal cues, so that only the first frame of a video needs an external point prompt and every subsequent frame is segmented from a propagated memory prompt instead. A memory reinforcement mechanism uses each frame's predicted mask to suppress speckle-noise features before they are written back into memory, addressing a key failure mode of naively adapting video object segmentation (e.g. XMem) to noisy ultrasound. Built on SAMUS (an ultrasound-adapted SAM) with a frozen SAM backbone and only the image-encoder adapter layers trained. On the semi-supervised CAMUS and EchoNet-Dynamic benchmarks (only end-diastole/end-systole frames labeled), MemSAM reaches 93.3% and 92.8% mean Dice respectively, outperforming UNet, SwinUNet, H2Former, and prior medical-SAM adaptations (MedSAM, MSA, SAMed, SonoSAM, SAMUS) with far fewer prompts, and derives LVEF (via Simpson's biplane method of disks) with a Pearson correlation of 78.9% against ground truth on CAMUS. Training/inference code is public (MIT license); only the starting SAM ViT-B checkpoint is linked for download, not a separately released fine-tuned MemSAM checkpoint.
Model ID: 0098
·
Subject Count: 10,530
Multimodal cardiac MRI foundation model that fuses 3D+T cine CMR (short-axis and long-axis views) with tabular patient health records (demographics, metabolic, and lifestyle factors) from 42,000 UK Biobank participants. Two-stage self-supervised pretraining -- masked-image reconstruction, then imaging-tabular contrastive alignment -- produces representations that transfer to whole-heart segmentation, cardiac phenotype/physiological-feature regression, and cardiac/metabolic disease classification within one unified framework.
Model ID: 0062
·
Subject Count: 74,916
Foundation model that encodes single-lead (lead I) ECGs with information from paired transthoracic echocardiography reports, aimed at label-efficient screening for structural heart disease (SHD) on wearable and portable single-lead ECG devices. A 7-layer 1D-CNN ECG encoder and a RoBERTa-based text encoder are contrastively pretrained (CLIP-style) on 194,551 ECG-echo report pairs from 77,378 adults in the Yale New Haven Health System, then the ECG encoder is fine-tuned on a temporally-distinct cohort to detect reduced LVEF, diastolic dysfunction, and a composite SHD label. Matches a randomly-initialized CNN at full training-data volume but substantially outperforms it in label-scarce regimes (e.g. with only 0.5% of labeled data).
Model ID: 0066
·
Subject Count: 77,378
Multi-agent LLM framework, deployed as a Software-as-a-Medical-Device on AWS, that assists cardiologists reading 24-hour Holter/patch ECG monitoring studies. Three fine-tuned LLM agents divide the diagnostic workflow the way a cardiologist would: a table-to-text agent (Llama-3.1-8B) extracts findings from tabular arrhythmia metrics, an image-to-text agent (LLaVA-v1.5-13B) extracts findings from ECG tracing images, and a findings-to-interpretation agent (Llama-3.1-8B) synthesizes both against clinical guidelines with a fact-checking step. Each agent is instruction-tuned on cardiologist-adjudicated reports from 2,000+ real-world patients and further steered at inference with in-context demonstrations matched to the patient's age, sex and arrhythmia class. In blinded cardiologist ratings across eight clinical/security metrics (1-5 scale), ZODIAC outperformed GPT-4o, Gemini-Pro, Llama-3.1-405B, Mixtral-8x22B, and medical-specialist LLMs (BioGPT, Meditron, Med42) on every metric while using under 30B total parameters, and has been integrated into commercial ECG monitoring devices. This is a proprietary product; no public code or model weights have been released.
Model ID: 0092
·
Subject Count: 2,000
Fully automated deep learning workflow for characterizing cardiac mechanics from balanced steady-state free-precession (bSSFP) cine cardiac MRI. It decouples two convolutional networks—a segmentation net (CarSON) and a 3D motion-estimation net (CarMEN)—to derive left- and right-ventricular volumes plus global and regional myocardial strain and strain rate without manual tracing. Trained and validated on healthy and cardiovascular-disease subjects and shown to be robust across MRI vendors, with excellent intra-scanner repeatability for strain. Developed at Massachusetts General Hospital and the Harvard-MIT Division of Health Sciences and Technology.
Model ID: 0056
·
Subject Count: 150
Open-source pipeline that classifies aortic stenosis (AS) severity from transthoracic echocardiography by combining structural and functional information. Video-based R(2+1)D convolutional networks read six B-mode and color Doppler views while a segmentation model measures peak aortic-jet velocity, and an ensemble integrates these into a final severity prediction. Trained on 210,193 images from Kaiser Permanente Northern California and validated across held-out, temporally distinct, and external Stanford and Cedars-Sinai cohorts, reaching AUCs up to 0.96–0.99 for severe AS. Developed by the Ouyang lab.
Model ID: 0054
Vision-language model that jointly embeds a cardiac MRI study, treated as video, with the impression section of its clinical report. Combines a video encoder over cine/LGE frame sequences with a Bio+ClinicalBERT text encoder using CLIP-style contrastive training. Supports zero-shot and few-shot classification of cardiomyopathies, amyloidosis, and LV dysfunction, plus image/report retrieval and structured report drafting. Trained on a private, single-institution corpus of roughly 11,000-14,000 CMR study-report pairs from Cleveland Clinic and Case Western.
Model ID: 0007
·
Subject Count: 12,500
Dual-encoder single-lead ECG classifier for atrial fibrillation detection that fuses a raw-signal branch with a spectrogram branch via axial attention and a Transformer. Originally developed as a graduate-course project at TU Darmstadt for the 2017 PhysioNet/CinC Challenge, and later extended in a 2023 follow-up study. Released in four sizes up to 130M parameters (S/M/L/XL), alongside a simpler CNN+LSTM variant.
Model ID: 0015
·
Subject Count: 11,000
Multimodal ECG model that pairs a 1D ConvNeXtV2 signal encoder with a BioLinkBERT text encoder, trained with a joint contrastive-and-captioning objective using LLM-generated descriptions of ECG demographics and waveform patterns in place of raw clinical reports. Validated on arrhythmia diagnosis and ECG-based subject identification, reaching an AUROC of 0.938 fine-tuned and 0.812 zero-shot on PTB-XL diagnostic classification. Developed at Rice University.
Model ID: 0019
·
Subject Count: 64,037
Vision-language foundation model fine-tuned from CLIP on more than one million private echocardiogram video-report pairs, enabling zero-shot cardiac function assessment, device identification, and image/text retrieval without task-specific training. Combines a ConvNeXt-Base video encoder with a GPT-2-style text encoder under contrastive pretraining. Training data is private, but model weights and code are public. Developed by Cedars-Sinai's Ouyang lab.
Model ID: 0035
End-to-end pipeline for apical-4-chamber echocardiogram videos that segments the left ventricle, estimates ejection fraction on a beat-to-beat basis, and classifies cardiomyopathy with reduced ejection fraction. Combines a DeepLabV3-ResNet50 segmentation model with a 3D CNN (R2+1D/R3D/MC3) initialized on the Kinetics-400 video dataset. Trained on the public EchoNet-Dynamic dataset released alongside it, and one of the most widely reused open echocardiography models since its 2020 Nature publication. Developed by Stanford University.
Model ID: 0036
·
Subject Count: 10,030
Measures interventricular septum thickness, LV internal diameter, and posterior wall thickness from PLAX echocardiogram videos, then classifies the underlying cause of left ventricular hypertrophy as either cardiac amyloidosis or hypertrophic cardiomyopathy. Combines an atrous-convolution 2D CNN for wall-thickness segmentation with a 3D residual CNN for etiology classification. Trained on 28,201 videos across Stanford, Cedars-Sinai, and the Unity Imaging Collaborative. Developed by Stanford University.
Model ID: 0040
Fully automated pipeline that scans a complete transthoracic echocardiogram study, identifies the apical-4-chamber color-Doppler clips showing the mitral valve, and grades mitral regurgitation severity at the study level. Combines a view/valve-presence classifier with a spatiotemporal CNN for severity classification. Trained on a private Cedars-Sinai cohort of 58,614 studies and externally validated on 915 studies from Stanford Healthcare.
Model ID: 0042
Automates standard echocardiographic measurements from video, pairing a measurement model with a companion segmentation component. Developed by Stanford and Cedars-Sinai's Ouyang lab; public documentation on the exact measurements covered, training data, and validation performance is limited compared to other EchoNet-family models.
Model ID: 0041
Detects 12 categories of echocardiogram-confirmed structural heart disease from 12-lead ECG waveforms combined with demographic and clinical covariates. Uses the same architecture as the original, larger EchoNext model but is trained entirely on the public EchoNext-Mini dataset - 100,000 de-identified ECGs from Columbia University Irving Medical Center released on PhysioNet - making it one of the more fully reproducible models of its kind, with public weights, a Docker image, and inference code.
Model ID: 0018
·
Subject Count: 36,286
Vision-language foundation model that interprets an entire transthoracic echocardiogram study rather than a single view or video: it classifies the view type of every clip, applies view-informed attention across the full study, and generates or retrieves comprehensive study-level interpretations in English or Italian. Pretrained on a private Cedars-Sinai corpus of 12 million echo video-report pairs. Developed by the Smidt Heart Institute and Stanford's Ouyang lab.
Model ID: 0039
Distills knowledge from EchoCLIP, a vision-language echocardiography model, into ECG embeddings, aiming to improve how well ECG signals alone can predict echo-derived measures of cardiac function. Combines a 1D ECG encoder with a BioBERT text encoder under a probabilistic cross-modal embedding objective that captures uncertainty. Published at MICCAI 2025 by the University of Toronto's McIntosh Lab.
Model ID: 0044
Ensemble of ten self-configuring nnU-Net models (five 2D, five 3D) that segments the left ventricle, right ventricle, and myocardium from short-axis cardiac cine MRI. Won the 2020 M&Ms challenge, a multi-centre, multi-vendor, multi-disease benchmark spanning scanners from four vendors and three countries, demonstrating strong generalization across acquisition protocols. Developed by DKFZ, the group behind the widely used nnU-Net framework.
Model ID: 0005
·
Subject Count: 350
Multimodal model that learns a shared representation space for ECG signals and their clinical text reports, pretrained on paired MIMIC-IV-ECG recordings and reports. Supports zero-shot ECG classification via text prompts, tested across six public benchmark datasets including PTB-XL and CPSC2018 without any downstream training data. Developed at Imperial College London and published at ICML 2024.
Model ID: 0033
·
Subject Count: 161,352
CLIP-style model that aligns 12-lead ECG signals with free-text echocardiography reports for zero-shot detection of structural heart disease directly from an ECG. Extends the MERL framework, and was trained on 45,016 paired ECG-echo reports from two Hong Kong hospitals, with external validation on the public EchoNext dataset from Columbia University. Developed by researchers at the University of Hong Kong and Imperial College London; described in a 2025 medRxiv preprint.
Model ID: 0045
View-agnostic, multi-task model that performs 39 different echocardiographic reporting tasks - covering chamber size and function, valve disease, and more - from any combination of views, aggregating clip-level predictions up to the study level. Combines a ConvNeXt-Tiny frame encoder with a temporal Transformer and separate output heads per task. Trained on private Yale-New Haven Health System echo videos and published in JAMA in 2025 by Yale's CarDS Lab.
Model ID: 0043
·
Subject Count: 24,405
Segments coronary vessels from invasive X-ray angiography images and automatically quantifies the degree of stenosis along the extracted centerlines. Combines MedSAM, a Segment-Anything-style vision model, with a Mamba-based VM-UNet segmentation branch for efficient long-range feature modeling. Trained and evaluated on the ARCADE, DCA1, and GH angiography datasets by researchers at Ocean University of China and Shandong University.
Model ID: 0001