Deep learning platform for fully automatic segmentation and phenotyping of coronary intravascular ultrasound (IVUS) pullbacks, packaged with a desktop GUI and CLI. A convolutional encoder-decoder network delineates the internal (lumen) and external elastic lamina borders on each cross-sectional IVUS frame; downstream rule-based analysis derives lumen area, plaque area, plaque burden, automatically flags lesions with plaque burden exceeding 40%, and reports minimum lumen area and maximum plaque burden along the pullback. Also supports end-diastolic gating and manual contour editing. Trained on 305 clinical IVUS pullbacks (270 train / 35 validation) from Philips and Boston Scientific catheters at Emory University; downstream evaluations have applied DeepIVUS to tasks such as automated detection of stent underexpansion.
Model ID: 0104
·
Subject Count: 305
Self-supervised model that performs single-frame digital-subtraction-angiography-style vessel/background separation directly from a single live (non-subtracted) coronary angiogram frame, then supports fine-tuned coronary vessel segmentation. A U-Net-style network is pretrained via an image-to-image translation objective on 58,128 unannotated angiography DICOM series (3,756 patients), then fine-tuned for vessel segmentation on just 40 expert-annotated frames, reaching a Dice of 0.828 on the held-out fine-tuning set and a new state-of-the-art Dice of 0.755 on the public XCAD benchmark. Intended to help clinicians visualize potential stenosis sites without requiring true two-frame digital subtraction acquisition.
Model ID: 0105
·
Subject Count: 3,796
nnU-Net-based segmentation network that detects and delineates stenotic lesions directly from X-ray coronary angiography frames, developed for the ARCADE (MICCAI 2023) stenosis-detection challenge. A companion model (YOLO-Angio, same team) handles vessel-tree segmentation; StenUNet focuses specifically on pixel-wise localization of stenotic regions. Placed 3rd overall among ARCADE challenge entrants with an F1 score of 0.5348 on the hold-out test set, within 0.0005 of the 2nd-place team.
Model ID: 0101
Open-weight video-based deep neural network that predicts reduced right-ventricular systolic function (RVSF) directly from routine left and right coronary angiogram videos, enabling real-time RV-dysfunction screening in the catheterization lab when echocardiography is unavailable. Built on an X3D-M spatiotemporal video architecture (Kinetics-400 pretrained) that aggregates per-video probabilities into a study-level normal-vs-reduced RVSF classification, with Grad-CAM/Guided-Backpropagation explainability confirming attention to RV-specific coronary motion rather than left-ventricular signal. Trained on 8,053 angiographic studies from 6,923 Montreal Heart Institute patients (2017-2023), externally validated at UCSF, and prospectively deployed at MHI via the PACS-AI platform, where AI assistance improved reader accuracy from 72.1% to 77.6% for cardiologists and 43.5% to 64.0% for medical students.
Model ID: 0073
·
Subject Count: 6,923