3 models found
·
3 public code
·
3 public weights
Deep learning platform for fully automatic segmentation and phenotyping of coronary intravascular ultrasound (IVUS) pullbacks, packaged with a desktop GUI and CLI. A convolutional encoder-decoder network delineates the internal (lumen) and external elastic lamina borders on each cross-sectional IVUS frame; downstream rule-based analysis derives lumen area, plaque area, plaque burden, automatically flags lesions with plaque burden exceeding 40%, and reports minimum lumen area and maximum plaque burden along the pullback. Also supports end-diastolic gating and manual contour editing. Trained on 305 clinical IVUS pullbacks (270 train / 35 validation) from Philips and Boston Scientific catheters at Emory University; downstream evaluations have applied DeepIVUS to tasks such as automated detection of stent underexpansion.
Model ID: 0104
·
Subject Count: 305
Translates a raw PPG waveform into a full continuous arterial blood-pressure waveform, from which systolic, diastolic, and mean arterial pressure are derived. Uses a two-stage cascaded 1D convolutional network in a U-Net style, with a coarse approximation stage followed by a refinement stage. Meets BHS Grade A and AAMI accuracy standards for diastolic and mean arterial pressure. Developed at BUET.
Model ID: 0049
Long-standing toolbox for automated segmentation of the ventricles and atria and derivation of cardiac imaging phenotypes from short- and long-axis cine cardiac MRI. Built on a fully convolutional network trained per slice, and widely reused across UK Biobank cardiac imaging studies since its 2018 publication. Developed at Imperial College London.
Model ID: 0006
·
Subject Count: 74,916