22 models found
·
20 public code
·
14 public weights
Lightweight convolutional neural network for binary ECG classification that represents ECG beats as spectrograms (via short-time Fourier transform) rather than raw signals, after denoising and frequency filtration to reduce data volume while preserving diagnostically relevant information. Using the large public PTB-XL dataset, the spectrogram-based CNN reached 99.06% accuracy, outperforming an equivalent raw-signal CNN, while also reducing memory usage and computation by avoiding complex architectures; the authors additionally studied the effect of signal up/down-sampling on classification performance.
Model ID: 0153
·
Subject Count: 18,885
CNN-based arrhythmia classifier that fuses the magnitude (scalogram) and phase (phasogram) of the continuous wavelet transform (CWT) of ECG heartbeats, rather than relying on magnitude information alone as most prior 2D-representation approaches do. Several fusion strategies (input-level, intermediate-layer, and output-level fusion) were compared on the public PhysioNet MIT-BIH Arrhythmia database. Despite a simple CNN architecture, the best fusion strategy achieved about 98.5% overall accuracy, 98.5% sensitivity and 95.6% specificity, competitive with more complex state-of-the-art approaches.
Model ID: 0143
·
Subject Count: 47
Regression-based convolutional neural network that directly estimates the heart-rate-corrected QT interval (QTc) from a 12-lead ECG, aiming to improve on automated QTc measurements from commercial ECG systems, which often diverge from expert readings. QTcNet was trained on 120,300 algorithm-labeled ECGs from an internal hospital cohort and the public MIMIC-IV database (after correcting for a vendor-specific measurement bias), and evaluated against expert QTc measurements in three independent external cohorts (PTB Diagnostic ECG Database, QTcMS, and ECGRDVQ). It roughly halved the mean absolute error compared with standard ECG analysis software (from 23.4ms to 13.4ms across external validation cohorts), with explainability analysis confirming the model focuses on physiologically plausible QRS-onset and T-offset regions.
Model ID: 0135
Multi-label 12-lead ECG diagnosis model submitted to the PhysioNet/Computing in Cardiology Challenge 2020, built on the same residual 1D CNN family as the authors' earlier Nature Communications model but retrained and validated across the challenge's large, multi-institutional pooled training set (CPSC2018, China 12-Lead ECG Database, St. Petersburg INCART, PTB and PTB-XL, and the Georgia 12-Lead ECG Database). The model uses an unsupervised pretraining stage -- predicting unseen samples of a partially masked ECG signal -- before supervised fine-tuning to jointly detect nine diagnostic classes (atrial fibrillation, first-degree AV block, left and right bundle branch block, normal rhythm, premature atrial/ventricular contraction, and ST-segment depression/elevation). The 2020 Challenge was notable for requiring every team to publicly release both their trained model weights and full training code, making this one of relatively few 12-lead ECG classifiers with an end-to-end reproducible public pipeline.
Model ID: 0118
·
Subject Count: 19,185
End-to-end deep learning model for detecting fetal QRS complexes directly from non-invasive abdominal ECG (aECG) signals, without requiring a separate reference maternal ECG or heavy hand-crafted feature engineering. The model adopts a ResNet architecture built from 1-D octave convolutions (OctConv), which factorize feature maps into high- and low-frequency components to capture multiple temporal frequency scales while reducing memory and compute cost relative to a standard 1-D ResNet; the resulting feature-importance weighting also highlights the signal regions most relevant to each detection. Evaluated on the PhysioNet/CinC Challenge 2013 fetal ECG database (with added Gaussian and motion-artifact noise to mimic real-world recording conditions), the model reached an F1 score of 91.1% while cutting computation by more than 50% for less than a 2% drop in performance versus a non-octave ResNet baseline.
Model ID: 0112
·
Subject Count: 75
Multi-outcome AI-ECG risk-estimation platform that turns a single 12-lead ECG into a patient-specific survival curve, using a residual convolutional neural network trained with a discrete-time survival loss to predict not just risk but time-to-event. Beyond all-cause and cardiovascular mortality, separately fine-tuned heads predict future ventricular arrhythmia, complete heart block, atrial fibrillation, atherosclerotic cardiovascular disease, heart failure, and (in follow-up work) hypertension -- all from a single resting ECG, including in ECGs a cardiologist would read as normal. Derived on 1.16 million ECGs from 189,539 Beth Israel Deaconess Medical Center patients and externally validated across transnational cohorts in the USA, Brazil (CODE), and the UK (UK Biobank). A variational autoencoder and genome/phenome-wide association analyses were used to show the model's predictions track biologically plausible features (QRS morphology, LV structure/function, and loci linked to cardiac structure, QT interval, and biological aging). NHS trials of AIRE were planned for late 2025. No public code or model weights have been released.
Model ID: 0089
·
Subject Count: 189,539
Multimodal deep-learning framework that estimates and forecasts abnormal laboratory values directly from a 12-lead ECG plus routinely available demographics, biometrics, and vital signs -- reframing dozens of blood tests as binary classification targets predictable from a test that is already fast, non-invasive, and nearly universal in acute care. A structured state-space (S4) encoder processes the raw ECG waveform and is late-fused with an MLP encoder over the tabular metadata; the same architecture is trained both to estimate the closest lab value within 60 minutes of the ECG ('abnormality prediction') and to forecast whether a value will become abnormal 30/60/120 minutes into the future ('abnormality forecasting'). Trained and evaluated on 385,480 linked ECG-lab-value samples from 127,994 MIMIC-IV patients, the model reaches AUROC > 0.7 for 24 distinct lab abnormalities in the prediction setting and 24 in the forecasting setting, spanning cardiac, renal, hematological, metabolic, immunological, and coagulation categories -- with NT-proBNP elevation the best-predicted marker (AUROC 0.90), followed by hemoglobin, albumin, and hematocrit derangements (AUROC > 0.82). Code for dataset construction, training, and evaluation is public under an MIT license; no pretrained model weights are released.
Model ID: 0100
·
Subject Count: 127,994
Supervised EfficientNetV2-based 12-lead ECG model trained on over 1 million ECGs from the Montreal Heart Institute to predict 77 cardiac conditions derived from American Heart Association recommendations, plus fine-tuned digital-biomarker heads for reduced LVEF, 5-year atrial-fibrillation risk, and long-QT-syndrome (LQTS) detection/genotyping. Validated on 881,403 ECGs across 11 geographically diverse cohorts (4 public, 7 private health systems), achieving AUROCs above 0.98 for the 77-condition interpretation task while being 60x smaller and 29x faster at inference than its self-supervised DeepECG-SSL counterpart, with up to 9.7x lower CO2 emissions on equivalent tasks.
Model ID: 0070
·
Subject Count: 184,210
Self-supervised EfficientNetV2-based 12-lead ECG foundation model pretrained via contrastive learning and masked-lead modeling on 1.9 million ECGs (Montreal Heart Institute plus CODE-15% and MIMIC-IV), then fine-tuned for the same 77-condition ECG interpretation task and digital-biomarker extraction as DeepECG-SL. Outperforms the supervised counterpart on label-scarce digital-biomarker tasks, with the largest gains on LQTS genotype classification (AUROC 0.931 vs. 0.850, n=127 ECGs) and 5-year atrial-fibrillation risk (AUROC 0.742 vs. 0.734, n=132,050 ECGs), and outperforms ECG-FM and ECGFounder on shared external diagnostic classes.
Model ID: 0071
·
Subject Count: 345,562
Explainable Inception-style 1D CNN for multi-label arrhythmia detection from 12-lead ECGs, integrating Grad-CAM visualization to highlight the waveform segments driving each prediction. Trained on MIMIC-IV-ECG and externally validated on PTB-XL across atrial fibrillation, sinus tachycardia, conduction disturbances (RBBB/LBBB/LAFB), long QT, Wolff-Parkinson-White pattern, and paced-rhythm detection, with all metrics exceeding 90% internally and strong generalization on external validation.
Model ID: 0064
·
Subject Count: 161,352
ECG foundation model designed to remain accurate when leads are missing or signals are noisy. A 1D ConvNeXt V2 encoder is trained with a dual-mode self-distillation objective (separate lead-missing and noise "teachers") alongside contrastive alignment to detailed diagnostic-criteria text reports retrieved via a lightweight, LLM-free "Cardiac Feature Retrieval" module. Consistently ranks best or second-best across PTB-XL diagnostic tasks and MIT-BIH arrhythmia classification under original, noisy, lead-missing, and combined-corruption conditions. Developed by FPT Software AI Center and the University of Arkansas.
Model ID: 0057
·
Subject Count: 180,237
CNN-based image classifier that screens 12-lead ECG images for a signature of transthyretin amyloid cardiomyopathy (ATTR-CM), producing a study-level probability score. Trained on a private Yale New Haven Health System cohort of nuclear-imaging-confirmed ATTR-CM cases and matched controls. Used alongside a companion echocardiography model to track pre-clinical ATTR-CM progression years before it would otherwise be confirmed by nuclear amyloid imaging. Developed by Yale's CarDS Lab and distributed as a packaged research-use executable rather than downloadable weights.
Model ID: 0024
EfficientNet-B3 CNN that detects hypertrophic cardiomyopathy directly from images of printed or scanned 12-lead ECGs, rather than from raw digital waveforms, enabling screening from a photo of a paper tracing. Initialized via self-supervised contrastive pretraining on patient identity, then fine-tuned at Yale New Haven Hospital on over 124,000 ECGs from about 67,000 patients, with HCM status confirmed by cardiac MRI or echocardiography. Externally validated on ECG images from MIMIC-IV, Amsterdam UMC, and UK Biobank. Developed by Yale's CarDS Lab.
Model ID: 0025
·
Subject Count: 66,987
Screens 12-lead ECGs for Chagas cardiomyopathy by first pretraining a feature extractor to predict blood-biomarker levels from MIMIC-IV-ECG data, then fine-tuning on Brazilian CODE-15%, SaMi-Trop, and PTB-XL recordings; the final model is a 5-model ensemble. Submitted to the George B. Moody PhysioNet Challenge 2025 (Detection of Chagas Disease from the ECG), where it placed 5th on the official leaderboard. Developed by a team from Akershus University Hospital and the University of Oslo.
Model ID: 0012
·
Subject Count: 1,631
1D residual neural network that screens 10-second, 12-lead ECG tracings for six common abnormalities: first- and second-degree AV block patterns, right and left bundle branch block, sinus bradycardia, atrial fibrillation, and sinus tachycardia. Reported F1 scores above 80% and specificity over 99% when benchmarked against cardiology residents. Developed at Universidade Federal de Minas Gerais and trained on the large Brazilian CODE-15% ECG dataset.
Model ID: 0010
Reconstructs digital 12-lead ECG waveforms from scanned or photographed paper printouts, using an nnU-Net image segmentation model to trace the signal pixels followed by a Hough-transform-based reconstruction pipeline. This is a digitization tool rather than a diagnostic model - it recovers a usable signal from a paper record rather than producing a diagnosis. Won the PhysioNet/Computing in Cardiology Challenge 2024; developed by a team at the University of Oxford.
Model ID: 0014
·
Subject Count: 18,885
1D residual neural network that predicts a patient's age directly from a 12-lead ECG; the gap between this predicted 'ECG age' and true chronological age is used as a biomarker of cardiovascular risk and mortality. Trained on the CODE-15% Brazilian ECG dataset, with the original R² of 0.71 later reproduced (R² = 0.70) in an independent German validation cohort. Developed by researchers at Uppsala University and UFMG.
Model ID: 0011
Multi-task 12-lead ECG model with output heads for incident atrial-fibrillation risk (as a survival curve), incident mortality risk, prevalent AF classification, sex classification, and age regression. Built on a 1D CNN over the raw waveform, and developed by the Broad Institute's ML4H group as a successor to their ECG-AI model published in Circulation. Trained on ECGs from UK Biobank and Massachusetts General Hospital, neither of which is publicly released.
Model ID: 0016
·
Subject Count: 45,770
Large-scale ECG foundation model pretrained on more than 10 million recordings spanning 150 label categories from the Harvard-Emory ECG Database. Built as a general-purpose feature extractor that can be fine-tuned for arrhythmia detection, demographic inference, and event prediction, and externally validated on MIMIC-IV-ECG and PTB-XL. Also used as the pretrained backbone for downstream clinical models such as Pocket-K, a hyperkalemia detector. Developed by Peking University and Harvard-Emory researchers.
Model ID: 0017
Self-supervised ECG representation learned purely from patient identity: the model is trained so that ECGs from the same patient, recorded at different times, map to nearby points in latent space, with no other labels required. Linear models trained on these representations showed a 51% average performance gain over training from scratch across sex classification, age regression, LVH detection, and AF detection. Developed by the Broad Institute's ML4H group and trained on 3.2 million private ECGs from Massachusetts General Hospital; 12-lead, lead-I-only, and lead-II-only checkpoints are all released.
Model ID: 0028
·
Subject Count: 404,929
Reference benchmark suite for the PTB-XL ECG dataset, providing pretrained xresnet1d, InceptionTime, LSTM, and CPC-pretrained models for 71-label, diagnostic, sub-diagnostic, and super-diagnostic classification of ECG findings. Widely used as a standardized baseline for comparing new ECG classification methods. Developed by Strodthoff et al. at Fraunhofer HHI.
Model ID: 0029
·
Subject Count: 18,885
Generative adversarial network that synthesizes realistic 10-second, 12-lead normal-sinus-rhythm ECGs from scratch, without using any real patient data at inference time, enabling privacy-preserving data sharing and augmentation. Uses a U-Net-style 1D deconvolutional generator with a WaveGAN-inspired discriminator. Outperformed a WaveGAN* baseline on the fraction of generated tracings classified as normal sinus rhythm by a commercial ECG interpretation algorithm. Developed by SimulaMet and Oslo Metropolitan University.
Model ID: 0030
·
Subject Count: 7,233