8 models found
·
8 public code
·
8 public weights
Reinforcement-learning-based unsupervised domain adaptation framework for spatio-temporal (2D+time) echocardiography segmentation, extending the authors' earlier RL4Seg work to full-length video sequences. RL4Seg3D uses a sliding-window approach supporting high-resolution, full-sized inputs, and fuses multiple reward mechanisms to improve segmentation reliability without requiring additional expert annotations in the target domain. Trained and evaluated on a large dataset of over 30,000 echocardiography videos, it outperforms baselines and foundation models on overall segmentation accuracy as well as echocardiography-specific metrics including anatomical/temporal validity and mitral-valve-commissure landmark precision, and supports test-time optimization via calibrated uncertainty estimates.
Model ID: 0159
The original U-Net baseline segmentation network introduced alongside the CAMUS (Cardiac Acquisitions for Multi-structure Ultrasound Segmentation) dataset, one of the largest fully open-access, expert-annotated 2D echocardiography benchmarks. The network segments the left ventricle endocardium (LVEndo), left ventricle epicardium/myocardium (LVEpi), and left atrium (LA) from apical 2-chamber and 4-chamber echo views at end-diastole (ED) and end-systole (ES). In the original ten-fold cross-validation benchmark comparing U-Net, U-Net++, Stacked Hourglass, Anatomically Constrained Neural Networks, and classical methods, the U-Net variant (18M parameters) achieved the best overall accuracy, reaching Dice scores of 0.939 (ED) / 0.916 (ES) for LVEndo and 0.954 (ED) / 0.945 (ES) for LVEpi, approaching inter-observer variability. A pretrained checkpoint of this baseline U-Net is distributed via the University of Sherbrooke's vitalab CASTOR project as part of a broader library for building anatomically-constrained cardiac segmentation pipelines.
Model ID: 0115
·
Subject Count: 500
Multimodal cardiac MRI foundation model that fuses 3D+T cine CMR (short-axis and long-axis views) with tabular patient health records (demographics, metabolic, and lifestyle factors) from 42,000 UK Biobank participants. Two-stage self-supervised pretraining -- masked-image reconstruction, then imaging-tabular contrastive alignment -- produces representations that transfer to whole-heart segmentation, cardiac phenotype/physiological-feature regression, and cardiac/metabolic disease classification within one unified framework.
Model ID: 0062
·
Subject Count: 74,916
Fully automated deep learning workflow for characterizing cardiac mechanics from balanced steady-state free-precession (bSSFP) cine cardiac MRI. It decouples two convolutional networks—a segmentation net (CarSON) and a 3D motion-estimation net (CarMEN)—to derive left- and right-ventricular volumes plus global and regional myocardial strain and strain rate without manual tracing. Trained and validated on healthy and cardiovascular-disease subjects and shown to be robust across MRI vendors, with excellent intra-scanner repeatability for strain. Developed at Massachusetts General Hospital and the Harvard-MIT Division of Health Sciences and Technology.
Model ID: 0056
·
Subject Count: 150
Vision-language model that jointly embeds a cardiac MRI study, treated as video, with the impression section of its clinical report. Combines a video encoder over cine/LGE frame sequences with a Bio+ClinicalBERT text encoder using CLIP-style contrastive training. Supports zero-shot and few-shot classification of cardiomyopathies, amyloidosis, and LV dysfunction, plus image/report retrieval and structured report drafting. Trained on a private, single-institution corpus of roughly 11,000-14,000 CMR study-report pairs from Cleveland Clinic and Case Western.
Model ID: 0007
·
Subject Count: 12,500
Foundation model for cine cardiac MRI, self-supervised via masked autoencoding on nearly 75,000 UK Biobank scans. Uses a Vision Transformer with a convolutional stem, unified across long-axis and short-axis views. Fine-tuned checkpoints are released for ventricle and myocardium segmentation, ejection-fraction regression, cardiovascular disease classification, and landmark localization across several public benchmark datasets (ACDC, M&Ms, M&Ms2, EMIDEC, and others).
Model ID: 0003
·
Subject Count: 74,916
End-to-end pipeline for apical-4-chamber echocardiogram videos that segments the left ventricle, estimates ejection fraction on a beat-to-beat basis, and classifies cardiomyopathy with reduced ejection fraction. Combines a DeepLabV3-ResNet50 segmentation model with a 3D CNN (R2+1D/R3D/MC3) initialized on the Kinetics-400 video dataset. Trained on the public EchoNet-Dynamic dataset released alongside it, and one of the most widely reused open echocardiography models since its 2020 Nature publication. Developed by Stanford University.
Model ID: 0036
·
Subject Count: 10,030
Long-standing toolbox for automated segmentation of the ventricles and atria and derivation of cardiac imaging phenotypes from short- and long-axis cine cardiac MRI. Built on a fully convolutional network trained per slice, and widely reused across UK Biobank cardiac imaging studies since its 2018 publication. Developed at Imperial College London.
Model ID: 0006
·
Subject Count: 74,916